25HPA6
Performancet Seri es 2---Stag e H e at Pump
with Puronr Refrigerant
2to5NominalTons
Installation Instruction
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code ( NEC ) NFPA 70.
In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.
Recognize safety information. This is the safety--alert symbol
!
!
.
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
Indoor Thermostat Control Options
Model
Infinity
Control
Standard
2 --- s t a g e
Thermostat
25HPA6 Yes Yes
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position
and install a lockout tag. There may be more than 1
disconnect switch. Lock out and tag switch with a
suitable warning label.
!
WARNING
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this warning could result in personal injury
or equipment damage.
PuronR refrigerant systems operate at higher pressures than
standard R--22 systems. Do not use R--22 service equipment
or components on PuronR refrigerant equipment.

Questions and Answers:

Carrier 25HPA6 Specifications

General IconGeneral
BrandCarrier
Model25HPA6
CategoryHeat Pump
LanguageEnglish

Summary

Safety Considerations

Installation Recommendations

Check Equipment and Job Site

Unpack and inspect unit, and check rating plate for job specifications.

Install on a Solid, Level Mounting Pad

Mount unit securely on a level pad, considering local codes and wind for stability.

Clearance Requirements

Ensure adequate space for airflow, wiring, piping, and service access for proper operation.

Operating Ambient

Elevate Unit

Make Piping Connections

Refrigerant System Connections

Install Liquid-Line Filter Drier Indoor

Install the required liquid-line filter drier in the liquid line for proper operation.

Refrigerant Tubing Connection Outdoor

Connect vapor and liquid tubing to the outdoor unit service valves.

Sweat Connections

Follow safety precautions when brazing refrigerant tubing connections.

Evacuate Refrigerant Tubing and Indoor Coil

Evacuate the system using the deep vacuum method to 500 microns for moisture removal.

Electrical Connections and Airflow

Electrical Connections

Wire ground, power, and control circuits according to diagrams and codes.

Airflow Selections

Configure blower airflow for ECM and variable speed furnaces based on cooling stages.

System Start-Up and Operation

System Start-Up

Follow safety and operational procedures during system start-up.

System Functions And Sequence Of Operation

Understand how the system operates in cooling and heating stages.

Advanced System Features

Infinity Controlled Low Ambient Cooling

Details on low ambient cooling capabilities and enablement with Infinity Control.

Defrost Operation

Explanation of defrost intervals, demand criteria, and termination conditions.

System Components and Troubleshooting

Major Components

Overview of key components like the control board, compressor, and contactor.

Troubleshooting

Diagnosing and resolving system issues using status codes and checks.

System Protection and Faults

Pressure Switch Protection

How high and low-pressure switches monitor and protect the unit.

Contactor and Compressor Faults

Detecting contactor issues, voltage problems, and compressor operation faults.

Sensor Information and Thermistor Faults

Temperature Thermistors

Details on thermistors for sensing air and coil temperatures.

Failed Thermistor Default Operation

Unit behavior when OAT or OCT sensors fail.

Status Codes and Troubleshooting Guide

Status Codes

Interpreting amber LED flashes for system diagnostics and fault identification.

Troubleshooting Table

Detailed fault codes, operations, and possible causes/actions for system issues.

Wiring Diagrams

Thermidistat Wiring (Non-Communicating)

Wiring diagram for non-communicating thermostats with 2-stage heat pump connection.

Thermidistat Wiring with Furnace (Non-Communicating)

Wiring diagram for non-communicating thermostats with furnace and heat pump.

Infinity Wiring (Communicating)

Wiring diagram for Infinity control setup with a communicating heat pump.

Final Checks and Maintenance

Final Checks

Essential checks to perform before leaving the job site for proper installation.

Care and Maintenance

Guidelines for continuing high performance and minimizing equipment failure.