30HXC 080-375
30GX 082-358
Screw Compressor
Water-Cooled Liquid Chillers and
Air-Cooled Liquid Chillers
30HXC Nominal cooling capacity 290-1325 kW
30GX Nominal cooling capacity 285-1205 kW
50 Hz
Installation, operation and maintenance instructions
GLOBAL CHILLER

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 30HXC175 and is the answer not in the manual?

Carrier 30HXC175 Specifications

General IconGeneral
BrandCarrier
Model30HXC175
CategoryChiller
LanguageEnglish

Summary

2- SAFETY CONSIDERATIONS

3- DIMENSIONS, CLEARANCES, WEIGHT DISTRIBUTION

9- APPLICATION DATA

9.8 - Evaporator pressure drop curve

9.9 - Condenser pressure drop curve

9.10 - Flow controllers

9.10.1 - Cooler flow switch and chilled water pump interlock

Installation and importance of cooler flow switch and pump interlock.

10 - INSTALLATION

10.1 - Check equipment received

Procedures for inspecting received unit for damage and completeness.

10.2 - Moving and siting the unit

Guidelines for safely moving and positioning the chiller unit.

11 - LIFTING INSTRUCTIONS

11.1 - 30HXC 080-190

Lifting instructions and dimensions for 30HXC 080-190 models.

11.2 - 30HXC 200-285

Lifting instructions and dimensions for 30HXC 200-285 models.

11.8 - Piping connections

12 - ELECTRICAL CHARACTERISTICS

13 - RECOMMENDED WIRE SECTIONS

14 - MAJOR SYSTEM COMPONENTS AND OPERATION DATA

14.1 - Geared twin screw compressor

Details on the 06N geared twin screw compressors used in the units.

15 - MAINTENANCE

15.1 - Refrigerant charging - adding charge

Procedures and precautions for adding refrigerant to the unit.

15.2 - Indication of low charge on a 30HXC system

How to identify and confirm low refrigerant charge in 30HXC units.

15.2.1 - To add charge to the 30HXC systems

Step-by-step guide for adding refrigerant to 30HXC units.

15.2.2 - Indication of low charge on 30GX systems

How to identify low refrigerant charge in 30GX systems.

15.8 - Compressor replacement

Critical considerations for compressor replacement.

15.8.2 - EXD Troubleshooting Procedure

Steps to diagnose and correct EXD or economizer problems.

16 - START-UP CHECKLIST FOR 30HXC/GX LIQUID CHILLERS

Unit start-up

Checklist items for unit start-up procedures.

Check cooler water loop

Checklist items for checking the cooler water loop.

Check pressure drop across the cooler

Checklist items for checking cooler pressure drop.

Check pressure drop across the condenser (30HXC only)

Checklist items for checking condenser pressure drop.

Perform TEST function (indicate positive result)

Checklist for performing and verifying the TEST function.

To start the chiller

Final checks before starting the chiller.