EasyManua.ls Logo

Carrier 30HXC100 User Manual

Carrier 30HXC100
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
30HXC 080-375
30GX 082-358
Screw Compressor
Water-Cooled Liquid Chillers and
Air-Cooled Liquid Chillers
30HXC Nominal cooling capacity 290-1325 kW
30GX Nominal cooling capacity 285-1205 kW
50 Hz
Installation, operation and maintenance instructions
GLOBAL CHILLER

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 30HXC100 and is the answer not in the manual?

Carrier 30HXC100 Specifications

General IconGeneral
RefrigerantR-134a
Voltage460 V
Compressor TypeScrew
Power Supply460/3/60
Sound Level78 dBA

Summary

Safety Considerations for Carrier Chillers

Critical Safety Warnings (DANGER)

Critical safety warnings regarding refrigerant venting, oxygen use, and pressure testing.

Operational Safety Warnings (WARNING)

Warnings about welding, electrical work, refrigerant handling, and cylinder safety.

Operational Precautions (CAUTION)

Precautions for refrigerant lines, climbing, automatic start arrangements, and water boxes.

Application Data

Unit Operating Range Specifications

Specifies the acceptable operating ranges for evaporator and condenser temperatures.

Installation Procedures

Moving and Siting the Unit

Guidance on safely moving and positioning the chiller unit.

Lifting Instructions

30HXC 080-190 Lifting Procedure

Diagram and notes for lifting 30HXC 080-190 models safely.

30HXC 200-285 Lifting Procedure

Diagram and notes for lifting 30HXC 200-285 models safely.

30HXC 310-375 Lifting Procedure

Diagram and notes for lifting 30HXC 310-375 models safely.

30GX 082-162 Lifting Procedure

Diagram and notes for lifting 30GX 082-162 models safely.

30GX 182 Lifting Procedure

Diagram and notes for lifting the 30GX 182 model safely.

30GX 207-267 Lifting Procedure

Diagram and notes for lifting 30GX 207-267 models safely.

30GX 298-358 Lifting Procedure

Diagram and notes for lifting 30GX 298-358 models safely.

Piping Connections and Hydraulic Circuits

Electrical Characteristics

30HXC/GX Power Supply and Voltage Imbalance

Power supply requirements and voltage imbalance limits for 30HXC/GX.

Major System Components

Maintenance Procedures

Refrigerant Charging Procedures

Safe procedures for charging refrigerant, including warnings.

Low Charge Indication and Addition

How to identify and diagnose low refrigerant charge and add refrigerant.

Start-Up Checklist

Related product manuals