INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS
Translation of the original document
* The availability of sizes and options depends on the country. Please contact your local commercial dealer for more information.
Air-Cooled Liquid Chillers
Reversible heat pumps
30RB/30RBP 170R-950R
Nominal cooling capacity 170-940 kW
30RQ/30RQP 165R-520R
Heating capacity 170-520 kW
Cooling capacity 155-485 kW
R-32

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 30RQ-180R and is the answer not in the manual?

Carrier 30RQ-180R Specifications

General IconGeneral
BrandCarrier
Model30RQ-180R
CategoryChiller
LanguageEnglish

Summary

Handling and Positioning

Handling

Guidelines for safely moving and lifting the unit using appropriate equipment and methods.

Positioning

Recommendations for selecting a suitable installation location and ensuring proper placement.

Physical and Electrical Data for the Units

Electrical Data 30RB 170R-380R

Contains electrical specifications including voltage, current, and power for 30RB units.

Electrical Data 30RBP 170R-950R

Details electrical data such as nominal voltage, current, and input power for 30RBP units.

Electrical Data 30RQ 165R-520R

Lists electrical data, including input power and current, for 30RQ units.

Electrical Data 30RQP 165R-520R

Provides electrical specifications, such as voltage and current draw, for 30RQP units.

Electrical Connection

Power Supply

Details requirements for the unit's power supply, including voltage and phase imbalance.

Water Connections

Frost Protection

Guidelines for preventing frost damage to unit components, especially in low temperatures.

Nominal System Water Flow Rate Control

System Start-Up

Checks Before System Start-Up

Comprehensive checklist for verifying the system and unit before initial operation.

Essential Points to Check

Key checks for compressors, hydraulic systems, and refrigerant charge before operation.

Main Components of the Unit and Operating Characteristics

SmartVu™ Control

Describes the features and interface of the SmartVu™ control system for unit management.

Options

Partial Heat Recovery (Option 49)

Explains the partial heat recovery option for producing hot water by desuperheating compressor discharge gases.

Total Heat Recovery (Option 50)

Describes the total heat recovery option for producing hot water from compressor discharge heat.

Free Cooling Operation

Explains the free cooling operation modes and corrosion protection requirements.

Standard Maintenance

Level 1 Maintenance

Outlines basic maintenance tasks that can be performed by the user.

Level 3 Maintenance

Describes advanced maintenance requiring specialized skills, tools, and manufacturer authorization.

Unit Start-Up Checklist for Installers Prior to Contacting the Manufacturer

Preliminary Equipment Check

Checklist for verifying shipping damage and ensuring the unit is properly installed and wired.

Unit Start-Up

Steps and checks required for the initial start-up of the chiller unit.