12
Default display Evaporator water
entering temp.
Discharge
pressure circuit A
Cooling setpoint 1 Contact 1: on/o/heating/
cooling
Output 1 SUB-MENU: User
Conguration (USEr)
Number of active
alarms/resets**
Historic alarm code 1** SUB-MENU:
Runtimes 1
Mode Evaporator water
leaving temp.
Suction pressure
circuit A
Cooling setpoint 2 Contact 2: setpoint selection Output 2 SUB-MENU: Service
Conguration
(SErviCE)
Active alarm code 1** Historic alarm code 2** SUB-MENU:
Runtimes 2
Chiller occupied mode* Outdoor temperature Discharge
pressure circuit B*
Ice storage setpoint* Contact 4: heating/cooling [1]* - SUB-MENU: Factory
Conguration
(FACtorY)
Active alarm code 2** Historic alarm code 3** SUB-MENU:
Runtimes 3
Minutes left Heat reclaim entering
water temp.*
Suction pressure
circuit B*
Heating setpoint 1* Contact 4: heat reclaim [2]*
OR free cooling prevention [2]
- - Active alarm code 3** Historic alarm code 4** SUB-MENU:
Maintenance
Cooling/heating
selection*
Heat reclaim leaving
water temp.*
Discharge
pressure circuit C*
Heating setpoint 2* User safety loop input status - - Active alarm code 4** Historic alarm code 5** -
Cooling/heating status* Saturated discharge
temperature circuit A
Suction pressure
circuit C*
Auto changeover
threshold (cooling mode)*
Water pump operation
contact status*
- - Active alarm code 5** Historic alarm code 6** -
Heat reclaim selection* Saturated suction
temp. circuit A
Vacuum pressure,
circuit A*
Auto changeover
threshold (heating mode)*
Control box thermostat - - - Historic alarm code 7** -
Total capacity in % Suction temperature,
circuit A
Vacuum pressure,
circuit B*
Heat reclaim mode input
setpoint*
Contact 3: demand limit
selection 1*
- - - Historic alarm code 8** -
Capacity circuit A in % Superheat, circuit A - Heat reclaim mode input
dead band*
Contact 3 bis: demand limit
selection 2*
- - - Historic alarm code 9** -
Capacity circuit B in % Saturated discharge
temp. circuit B
- Setpoint demand
limitation 1*
Ice storage remote contact* - - - Historic alarm code 10** -
Capacity circuit C in
%*
Saturated discharge
temp. circuit B
- Setpoint demand
limitation 2*
Remote unit contact,
continued occupied mode*
- - - Historic alarm code 11** -
Present demand limit
in %
Suction temperature,
circuit B
- Setpoint demand
limitation 3*
User safety loop input* - - - Historic alarm code 12** -
Present lag limit in %* Superheat, circuit B - Ramp loading* Demand limit control
limitation value*
- - - Historic alarm code 13** -
Setpoint in local
control
Saturated discharge
temp. circuit C*
- Cooling - zero reset
threshold*
Setpoint reset value* - - - Historic alarm code 14** -
Setpoint occupied
mode
Saturated discharge
temp. circuit C*
- Cooling - full reset
threshold*
Ambient temperature value* - - - Historic alarm code 15** -
Active setpoint Suction temperature,
circuit C*
- Cooling - full reset value* Subcooling liquid
temperature, circuit A*
- - - Historic alarm code 16** -
Control point Superheat, circuit C* - Heating - zero reset
threshold*
Subcooling liquid
temperature, circuit B*
- - - Historic alarm code 17** -
Controlled water
temperature
Defrost temperature,
circuit A*
- Heating - full reset
threshold*
Subcooling temperature,
circuit A*
- - - Historic alarm code 18** -
Indicator, heat recovery
in progress, circuit A*
Defrost temperature,
circuit B*
- Heating - full reset value* Subcooling temperature,
circuit B*
- - - Historic alarm code 19** -
Indicator, heat recovery
in progress, circuit B*
System water
temperature*
- - - - - - Historic alarm code 20** -
* Displayed if the conguration requires it 1 For heat pump units
** Displayed if the alarm exists 2 For cooling only units
- Not in use