ACCESSORIES
The system is shipped with the following accessories (see Table 3). Keep
the owner's manual in a safe place and do not discard any accessories
until the installation has been completed.
Table 3 — Accessories
INDOOR UNIT PARTS AND MAJOR
FUNCTIONS
Unit Parts
Fig. 1 — Unit Parts
Operating Conditions
Use the system under the following temperatures for safe and effective
operation. If the air conditioner is used under different conditions, it may
malfunction or become less efficient.
Table 4 — Inverter Split Type
For Outdoor Units With Auxiliary Electric Heater
When the outside temperature is below 32°F (0°C), we strongly
recommend keeping the outdoor unit powered at all times to prevent
damage to the equipment.
NOTE: Room relative humidity less than 80%. If the air conditioner
operates in excess of this figure, the surface of the air
conditioner may attract condensation.
Name Image Quantity
Owner’s and Installation Manual 2
Remote Controller 1
Batteries 2
Suction Line Flare to Braze Adapter
3/4” (All Sizes)
1
Liquid Line Flare to Braze Adapter
3/8” (All Sizes)
1
Fastening Belt 2
Insulation Sleeve
N/A
1
Sponge 4
Flare Nut (18K-60K) 2
COOL Mode HEAT Mode Dry Mode
Room
Temperature
60°F - 90°F
(16°C - 32°C)
32°F - 86°F
(0°C - 30°C)
50°F - 90°F
(10°C - 32°C)
Outdoor
Temperature
-22°F - 122°F
(-30°C - 50°C)
(For Hyper
Heat Series)
-22°F - 75°F
(-30°C - 24°C)
(For Hyper
Heat Series)
32°F - 122°F
(0°C - 50°C)
-13°F - 122°F
(-25°C - 50°C)
(For Regular
Heat Series)
-13°F - 75°F
(-25°C - 24°C)
(For Regular
Heat Series)
Air outlet
Air inlet

Related product manuals