Carrier 38AH024-034 User Manual

Carrier 38AH024-034
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Carrier 38AH024-034 and is the answer not in the manual?

Carrier 38AH024-034 Specifications

General IconGeneral
Model38AH024-034
TypeAir Conditioner
RefrigerantR-410A
Phase1
Cooling Capacity24, 000 BTU
Voltage208/230V
HSPFNot Applicable

Summary

Safety Considerations

Electric Shock Hazard

Critical safety warning regarding electrical shock hazards during servicing.

Pre-Start-Up

Leak Test and Dehydration

Steps for leak testing the refrigerant system and performing dehydration using specified methods.

Preliminary Charge

Guidelines for charging the system with R-22 refrigerant using the liquid charging method.

Start-Up

Preliminary Checks

Essential checks before unit start-up, including valve positions, electrical connections, and oil levels.

Start Unit

Steps to safely start the condensing unit, including initial settings and breaker operations.

Adjust Refrigerant Charge

Method for adjusting refrigerant charge based on pressure and temperature readings for optimal performance.

Check Compressor Oil Level

Procedure to verify compressor oil levels after adjusting refrigerant charge under loaded conditions.

Sequence of Operation

Causes of Complete Unit Shutdown

Lists common reasons for the complete shutdown of the unit, including safety trips.

Service

Oil Pressure Safety Switch (OPS)

Role of the OPS in stopping the compressor and unit if oil pressure is insufficient.

Troubleshooting

Compressor Does Not Run

Identifies problems and solutions when the compressor contactor is open or closed.

Compressor Stops on High-Pressure Switch

Troubleshooting steps for when the compressor stops due to a high-pressure switch trip.

Compressor Cycles on Low-Pressure Switch

Diagnosing issues when the compressor cycles on the low-pressure switch.

Compressor Stops on Oil Pressure Switch

Compressor Running But Cooling Insufficient

Diagnosing and resolving issues related to insufficient cooling while the compressor is running.

Start-Up Checklist

B. Pre-Start-Up

Checklist items for the outdoor unit, controls, indoor unit, and piping before start-up.

Check Voltage Imbalance

Procedure for checking voltage imbalance and understanding its impact on system start-up.

C. Start-Up

Check the Compressor Oil Level Sight Glasses; Are the Sight Glasses Showing Oil Level in View?

Verify that compressor oil levels are visible in the sight glasses.