13
START−UP
Test Operation
Perform a test operation after completing a gas leak and electrical
safety check. See the indoor unit installation instructions and
owner’s manual for additional start up information.
SYSTEM CHECKS
1. Conceal the tubing where possible.
2. Make sure that the drain tube slopes downward along its
entire length.
3. Ensure all tubing and connections are properly insulated.
4. Fasten the tubes to the outside wall, when possible.
5. Seal the hole through which the cables and tubing pass.
OUTDOOR UNIT
1. Are there unusual noises or vibrations during operation?
Explain the Following Items to the Customer (with the aid of
the Owner’s Manual):
1. Explain care and maintenance.
2. Present the installation instructions to the customer.
OUTDOOR UNIT DIAGNOSTIC GUIDES
For ease of service, the systems are equipped with a diagnostic code display LEDs on both the indoor and outdoor units. The outdoor
diagnostic is displayed on the outdoor unit microprocessor board.
There may be a few error codes displayed in the indoor unit that might relate to the outdoor unit’s problems. If possible, always check the
diagnostic codes displayed on the indoor unit first.
The diagnostic codes displayed on the outdoor units are listed on Table 11.
Table 11—Unit Diagnostic Guides
DISPLAY LED STATUS
E1 Communication malfunction between indoor and outdoor units.
F0 Protection of over-current
F1 Open circuit or short circuit of outdoor ambient temperature sensor T4
F2 Open circuit or short circuit of condenser coil temperature sensor T3
F3 Open circuit or short circuit of Compressor discharge temperature sensor T5
F4 Outdoor unit EEPROM error
F5 Outdoor fan speed has been out of control
P0 IPM malfunction
P1 Over voltage or over low voltage protection
P2 High temperature protection of compressor top
P3 Outdoor low temperature protection
P4 Inverter compressor drive error
P7 Outdoor IGBT temperature sensor error
J0 High temperature protection of indoor coil in heating
J1 Outdoor temperature protection of outdoor coil in cooling
J2 Discharge temperature protection
J3 Protection of active PFC module
J4 Communication error between control board and IPM board
J5 High-pressure switch protection
J6 Low-pressure switch protection
J8 AC voltage protection
For additional diagnostic information, refer to the Service Manual.

Other manuals for Carrier 38MHRBQ24AA3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38MHRBQ24AA3 and is the answer not in the manual?

Carrier 38MHRBQ24AA3 Specifications

General IconGeneral
Model38MHRBQ24AA3
RefrigerantR-410A
Voltage208/230V
Phase1
Compressor TypeInverter
StagesVariable
Cooling Capacity24, 000 BTU/h
HSPF Rating10.0
Sound Level (dB)55 dB
Sound Pressure Level (Outdoor Unit)55 dBA
TypeDuctless Mini-Split