EasyManua.ls Logo

Carrier 38MVC - User Manual

Carrier 38MVC
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Product Data
40MVC / 38MVC
40MVQ / 38MVQ
High---W all Duct F ree Split System
Sizes 009 to 024
the environmentally sound refrigerant
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.
INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38/40MVC(Q) series duct--free split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
S Add--ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.

Other manuals for Carrier 38MVC

Questions and Answers

  • J
    jellisAug 8, 2025
    What to do if indoor room temp or evaporator sensor is open circuit or short circuited in Carrier 38MVC?
    • S
      Sarah AndersonAug 8, 2025
      If the indoor room temperature or evaporator sensor in your Carrier Air Conditioner is open circuit or short-circuited, check the diagnostic codes displayed on the indoor unit first to identify the problem.
  • C
    Crystal Nelson MDAug 13, 2025
    What to do if there is an indoor unit communication error (Illuminates simultaneously) in my Carrier Air Conditioner?
    • J
      Jeremy IrwinAug 14, 2025
      If your Carrier Air Conditioner displays an indoor unit communication error (illuminating simultaneously), check the diagnostic codes displayed on the indoor unit first to identify the problem.
  • M
    Michael RossAug 20, 2025
    What to do if compressor over-current protection has been activated four times in Carrier 38MVC Air Conditioner?
    • Y
      ydavisAug 20, 2025
      If the compressor over-current protection in your Carrier Air Conditioner has been activated four times, check the diagnostic codes displayed on the indoor unit first to understand the issue.
  • T
    tburkeAug 26, 2025
    How to fix indoor fan speed that has been out of control for over 1 minute in Carrier 38MVC?
    • K
      Katie BrownAug 26, 2025
      If the indoor fan speed of your Carrier Air Conditioner has been out of control for more than 1 minute, check the diagnostic codes displayed on the indoor unit first to diagnose the issue.
  • M
    Michael RogersAug 31, 2025
    How to fix EEROM error in Carrier 38MVC Air Conditioner?
    • M
      Matthew HortonAug 31, 2025
      If your Carrier Air Conditioner is showing an EEROM error, check the diagnostic codes displayed on the indoor unit first to troubleshoot the issue.

Summary

Product Data

Industry Leading Features;Benefits

Key advantages and solutions offered by the duct-free split system.

System Operation and Benefits

Key Operational Features

Covers sound, security, installation, servicing, reliability, comfort, economy, controls, accessories, and agencies.

Model Number Nomenclature

Indoor Unit Nomenclature

Explanation of the indoor unit model coding.

Outdoor Unit Nomenclature

Explanation of the outdoor unit model coding.

Standard Features and Accessories

Standard Features

Lists the standard features for indoor and outdoor units.

AHRI Capacity Ratings

Provides cooling and heating capacity data.

Dimensions and Service Valve Locations

Indoor Unit Dimensions

Physical sizes and weights of indoor units.

Outdoor Unit Dimensions

Physical sizes and weights of outdoor units.

Service Valve Locations

Indicates positions of service valves on outdoor units.

Unit Clearances

Indoor Unit Clearances

Required spacing for indoor unit airflow.

Outdoor Unit Clearances

Required spacing for outdoor unit airflow.

Physical Data - Outdoor Units

Outdoor Unit 38 MVC

Technical specifications for 38MVC outdoor units.

Outdoor Unit 38 MVQ

Technical specifications for 38MVQ outdoor units.

Physical Data - Indoor Units

Indoor Unit 40 MVC

Technical specifications for 40MVC indoor units.

Indoor Unit 40 MVQ

Technical specifications for 40MVQ indoor units.

Physical Data - Indoor Units (Continued)

Indoor Unit 40 MVQ (Continued)

Continued technical specifications for 40MVQ indoor units.

Performance Data - Cooling Capacities

Cooling Capacities 38 MVC(Q)009-1

Performance data for 9K cooling units.

Cooling Capacities 38 MVC(Q)012-1

Performance data for 12K cooling units.

Performance Data - Cooling Capacities (Continued)

Cooling Capacities 38 MVC(Q)012-3

Performance data for 12K cooling units (208/230V).

Cooling Capacities 38 MVC(Q)018-3

Performance data for 18K cooling units.

Performance Data - Cooling Capacities (Continued)

Cooling Capacities 38 MVC(Q)018-3 (Continued)

Performance data for 18K cooling units (continued).

Cooling Capacities 38 MVC(Q)024-3

Performance data for 24K cooling units.

Performance Data - Cooling Capacities (Continued)

Cooling Capacities 38 MVC(Q)024-3 (Continued)

Performance data for 24K cooling units (continued).

Performance Data - Cooling Capacities (Continued)

Cooling Capacities 38 MVC(Q)024-3 (Continued)

Performance data for 24K cooling units (continued).

Performance Data - Heating Ratings

Instantaneous and Integrated Heating Ratings 38 MVQ009-1

Heating performance for 9K heat pump units.

Performance Data - Heating Ratings (Continued)

Instantaneous and Integrated Heating Ratings 38 MVQ012-1

Heating performance for 12K heat pump units.

Performance Data - Heating Ratings (Continued)

Instantaneous and Integrated Heating Ratings 38 MVQ012-3

Heating performance for 12K heat pump units (208/230V).

Performance Data - Heating Ratings (Continued)

Instantaneous and Integrated Heating Ratings 38 MVQ018-3

Heating performance for 18K heat pump units.

Performance Data - Heating Ratings (Continued)

Instantaneous and Integrated Heating Ratings 38 MVQ024-3

Heating performance for 24K heat pump units.

Application Data

System Operating Conditions

Defines operational temperature and humidity ranges.

Low Ambient Operation

Details performance in cold conditions.

Metering Devices

Describes the system's metering devices.

Drain Connections

Guidelines for condensate drainage.

Refrigerant Lines and Controls

Refrigerant Lines

Sizing, insulation, and long-line considerations.

Control System

Microprocessor control functions and modes.

Wireless Remote Control

Operation via remote.

Technical Data and Ratings

Air Throw Data

Information on air circulation distances.

Sound Ratings

Noise levels measured from units.

Electrical Data

Power requirements and electrical specifications.

Guide Specifications - Indoor Units

System Description & Agencies

Overview of functionality, design, and compliance.

Equipment Details

Covers general, cabinet, fans, coil, motors, and controls.

Electrical & Performance Specs

Covers electrical requirements, SEER, HSPF, and refrigerant lines.

Special Features (Field Installed)

Optional field-installed features.

Guide Specifications - Outdoor Units

System Description & Agencies

Overview of functionality, design, and compliance.

Equipment Details

Covers general, cabinet, fans, compressor, coil, and refrigeration components.

Controls, Safeties & Electrical

Covers operational controls, safeties, and electrical requirements.

Special Features (Field Installed)

Optional field-installed features.

Carrier 38MVC Specifications

General IconGeneral
SEERUp to 20.5
RefrigerantR-410A
SEER RatingUp to 20.5
Voltage208-230V
Dimensions (Outdoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model