Combination ratings* continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (-9°C) db 15°F (–10°C) wb air entering outdoor unit.
Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
Requires hard shutoff TXV; based on computer simulation.
** TDR is on all furnaces, except 58GFA.
UNIT SIZE-
SERIES
AND
SOUND
RATING
(dBA)
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
High-Temp Low-Temp Seasonal
Efficiency
HSPF/HSPF
with LSV
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
TXV
TXV&TDR**
TC COP TC COP
060-30
75
FK4CNB006† 59,000 TDR & TXV 12.50 61,000 3.32 39,000 2.58 8.30/8.50
F(A,B)4AN(F,B)060 57,500 TDR 11.50 61,000 3.06 39,500 2.40 7.80/8.20
FB4ANB070 58,500 TDR 12.00 61,000 3.22 39,500 2.48 8.00/8.20
FC4BN(F,B)060 57,500 TDR & TXV 11.50 61,000 3.06 39,500 2.40 7.80/8.00
FC4BNB070 58,500 TDR & TXV 12.00 61,000 3.22 39,500 2.48 8.00/8.20
FG3AAA060 56,500 None 11.50 61,000 2.94 39,000 2.36 7.50/7.70
FK4BNB006 59,000 TDR & TXV 12.50 61,000 3.30 39,000 2.54 8.30/8.50
CC5A/CD5A/CD5BA060 55,500 None 11.50 61,000 2.82 38,500 2.30 7.30/7.50
CC5A/CD5A/CD5BW060 56,500 None 11.50 61,000 3.00 39,000 2.40 7.70/7.90
CD3(A,B)A060 55,500 None 11.50 61,000 2.82 38,500 2.30 7.30/7.50
CE3AA060 57,500 None 12.00 61,000 3.00 39,000 2.40 7.70/7.90
CJ5A/CK5A/CK5BA060 57,500 None 11.50 61,000 2.94 39,000 2.38 7.50
CJ5A/CK5A/CK5BN060 57,500 None 11.50 61,000 2.94 39,000 2.38 7.50
CJ5A/CK5A/CK5BX060 58,000 None 12.00 61,000 3.08 39,000 2.44 7.80
CK3BA060 57,500 None 11.50 61,000 2.94 39,000 2.38 7.50
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,000 TDR 11.20 61,000 2.80 39,500 2.30 7.20/7.40
CD3(A,B)A060 55,000 TDR 11.20 61,000 2.80 39,500 2.30 7.20/7.40
CC5A/CD5A/CD5BW060 56,500 TDR 11.50 61,000 3.00 39,500 2.40 7.50/7.70
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,500 TDR 11.50 61,000 2.84 38,500 2.32 7.20/7.40
CD3(A,B)A060 55,500 TDR 11.50 61,000 2.84 38,500 2.32 7.20/7.40
CC5A/CD5A/CD5BW060 57,000 TDR 12.00 61,000 3.04 39,000 2.44 7.80/8.00
CE3AA060 57,500 TDR 12.00 61,000 3.02 39,000 2.42 7.80/8.00
CJ5A/CK5A/CK5BA060 57,500 TDR 12.00 61,000 2.94 38,500 2.40 7.50
CJ5A/CK5A/CK5BX060 58,500 TDR 12.20 61,000 3.12 38,500 2.48 7.80
CK3BA060 57,500 TDR 12.00 61,000 2.94 38,500 2.40 7.50
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,000 TDR 11.50 61,000 2.80 39,000 2.30 7.20/7.40
CD3(A,B)A060 55,000 TDR 11.50 61,000 2.80 39,000 2.30 7.20/7.40
CC5A/CD5A/CD5BW060 56,500 TDR 12.00 61,000 3.02 39,000 2.42 7.50/7.70
CE3AA060 57,500 TDR 12.00 61,000 3.00 39,000 2.42 7.50/7.70
CJ5A/CK5A/CK5BA060 57,500 TDR 11.80 61,000 2.96 38,500 2.38 7.50
CJ5A/CK5A/CK5BX060 58,000 TDR 12.00 61,000 3.10 38,500 2.46 7.80
CK3BA060 57,500 TDR 11.80 61,000 2.96 38,500 2.38 7.50
SEER Seasonal Energy Efficiency Ratio LSV Liquid Solenoid Valve
COP Coefficient of Performance TDR Time-Delay Relay
HSPF Heating Seasonal Performance Factor TXV Thermostatic Expansion Valve
TC Total Capacity (Btuh)