2               Specifications subject to change without notice.                    IM-40MBAA-01
INTRODUCTION
The Air Handler models are R-410A Fan Coils designed for 
installation flexibility allowing multi-position installation Upflow, 
down flow, horizontal right & horizontal left. These units leave the 
factory compliant with low leak requirements of
 less than 2% cabinet 
leakage rate at 0.5 inches W.C. when tested in accordance with 
ASHRAE 193 standard.
The metering device is installed on the outdoor unit and the fan coils 
do not have the device. All fan coils have a DC fan motor with 
variable speeds for efficiency. The units have been designed for up-
flow, down-flow, and horizontal orientations, including manufactured 
and mobile home applications.
These units require a field supplied air filter, and are designed 
specifically for R-410A refrigerant heat pumps. These units are 
available for systems of 24,000 through 48,000 BTUh nominal 
cooling capacity.
 
HEATER PACKAGES
This unit is not equipped with an electric heater package. A factory-
approved, field-installed, ETL listed heater package is available from 
your equipment supplier. Factory-authorized, field-installed electric 
heater packages are available in sizes 5kW through 20kW. Electric 
heaters that are not factory approved could cause damage which 
would not be covered under the equipment warranty. Review the 
product data literature for all available accessory kits.
Table 1 — Indoor Unit Model Numbers
ACCESSORIES
The system is shipped with the following accessories (see Table 2). Use 
all of the installation parts and accessories to install the system. Improper 
installation may result in water leakage, electrical shock and fire, or cause 
the equipment to fail. Keep the installation manual in a safe place and do 
not discard any accessories until the installation has been completed.
Table 2 — Accessories 
NOTE: *The wireless remote controller is used only for initial static 
pressure and airflow setup.
Fig. 2 — Air Regulator
Fig. 3 — Indoor Unit Representation
KBTUH V-PH-HZ ID MODEL NO.
24
208/230-1-60
40MBAAQ24XA3
36 40MBAAQ36XA3
48 40MBAAQ48XA3
EXPLOSION HAZARD
Failure to follow this warning could 
result in death, serious personal injury, 
and/or property damage.
Never use air or gases containing oxygen 
for leak testing or operating refrigerant 
compressors. Pressurized mixtures of air 
or gases containing oxygen can lead to 
an explosion.
WA R N I N G
INSTALLATION
Entrust a licensed contractor to install the unit. Installation by 
unskilled persons may lead to improper installation, electric shock, 
or fire. Re-installation must be performed by authorized 
professionals. Non-compliance may lead to electric shock or fire.
WA R N I N G
This unit is NOT equipped with a single point electrical 
connection for an Auxiliary Heat Package. A separate power 
supply is required for the Auxiliary Heat Package.”
CAUTION
NAME SHAPE QUANTITY
Owner’s and 
Installation 
Manual
1
Wireless Remote 
Controller*
1
Battery 1
Infrared Display Panel 
and 
Extension Wire (located 
on the Air Handler Unit)
1
Optional Return 
Temperature 
Sensor p/n 40VM900009 - 
sold separately
1
ON/OFF
TEMP
FP
TIMER
  ON
TIMER
  OFF
MODE
FAN/SLC
SLEEP
TURBO
SWING
DIRECT
CLEAN
LED
FOLLOW
Air outlet
Air inlet
Drain hose
Refrigerant 
connecting 
pipe
Coil Compartment
(Access Panel Removed)