EasyManua.ls Logo

Carrier 40MVQ - User Manual

Carrier 40MVQ
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Product Data
40MVC / 38MVC
40MVQ / 38MVQ
High---W all Duct F ree Split System
Sizes 009 to 024
the environmentally sound refrigerant
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.
INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38/40MVC(Q) series duct--free split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
S Add--ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.

Other manuals for Carrier 40MVQ

Questions and Answers:

Carrier 40MVQ Specifications

General IconGeneral
Model40MVQ
RefrigerantR-410A
TypeDuctless Mini-Split
Compressor TypeInverter
Sound Level19 dB (Indoor), 54 dB (Outdoor)
Outdoor Unit Noise Level54 dB
Indoor Unit Dimensions (WxHxD)Varies by model
Outdoor Unit Dimensions (WxHxD)Varies by model
Indoor Unit WeightVaries by model
Outdoor Unit WeightVaries by model
Air Flow (Indoor Unit)Varies by model
Power Supply208/230V, 1Ph, 60Hz

Summary

Product Data

Industry Leading Features; Benefits

Overview of key advantages like cost-effectiveness and design solutions for various applications.

Product Features and Benefits

Low Sound Levels

Explains the quiet operation of duct-free split systems due to no indoor compressors or ductwork.

Secure Operation

Details how units prevent intruders and protect coils from weather due to piping and wiring connections.

Fast Installation

Highlights the simplicity of installation, requiring only wiring and piping between units, minimizing disruption.

Simple Servicing and Maintenance

Describes easy access for service, cleanable filters, and self-diagnostics for troubleshooting.

Built-in Reliability

Discusses design for years of trouble-free operation with protections against freeze-ups and high temperatures.

Individual Room Comfort

Focuses on personalized comfort through individual space control and air sweep features.

Economical Operation

Explains cost savings from heating/cooling only required spaces and efficient air movement.

Easy-to-Use Controls

Mentions microprocessor-based controls and user-friendly wireless remote for comfort and efficiency.

Accessories

Lists optional accessories like low-ambient kits and condensate pumps for customization.

Agency Listings

States that systems are listed with ARI and ETL for compliance.

Model Number Nomenclature

Indoor Unit Nomenclature

Explains the coding for indoor unit model numbers, including type and capacity.

Outdoor Unit Nomenclature

Details the coding for outdoor unit model numbers, including type and capacity.

Standard Features and Accessories

Indoor Unit Features

Lists standard features like mounting brackets, controls, air sweep, and freeze protection.

Outdoor Unit Features

Details features like low-ambient kits and crankcase heaters for outdoor units.

Unit Dimensions

Indoor Unit Dimensions

Provides width, height, depth, and operating weight for indoor units.

Outdoor Unit Dimensions

Specifies dimensions (W, H, L1, L2, L3) and weights for outdoor units.

Service Valve Locations

Details the positions of service valves (J and K) for various unit sizes.

Unit Clearances

Indoor Unit Clearances

Specifies minimum clearances required around the indoor unit for proper airflow.

Outdoor Unit Clearances

Details minimum clearances for outdoor unit airflow from all sides.

Physical Data

Outdoor Unit Physical Data

Presents detailed physical specifications for outdoor units, including capacity, weight, and coil data.

Indoor Unit 40 MVC Physical Data

Indoor Unit 40 MVQ Physical Data

Cooling Performance Data

Cooling Performance Data - 009;012 Units

Presents cooling capacities for 009 and 012 model sizes across various conditions.

Cooling Performance Data - 012;018 Units

Provides cooling capacities for 012 and 018 model sizes across various conditions.

Cooling Performance Data - 018;024 Units

Details cooling capacities for 018 and 024 model sizes across various conditions.

Cooling Performance Data - 018-3 Units

Specifies cooling capacities for the 018-3 model size across various conditions.

Cooling Performance Data - 024-3 Units

Presents cooling capacities for the 024-3 model size across various conditions.

Heating Performance Data

Heating Ratings - 38 MVQ009-1;40 MVQ009-1

Lists instantaneous and integrated heating ratings for 38MVQ009-1/40MVQ009-1 units.

Heating Ratings - 38 MVQ012-1;40 MVQ012-1

Lists instantaneous and integrated heating ratings for 38MVQ012-1/40MVQ012-1 units.

Heating Ratings - 38 MVQ012-3;40 MVQ012-3

Lists instantaneous and integrated heating ratings for 38MVQ012-3/40MVQ012-3 units.

Heating Ratings - 38 MVQ018-3;40 MVQ018-3

Lists instantaneous and integrated heating ratings for 38MVQ018-3/40MVQ018-3 units.

Heating Ratings - 38 MVQ024-3;40 MVQ024-3

Lists instantaneous and integrated heating ratings for 38MVQ024-3/40MVQ024-3 units.

Application Data

Unit Selection Guidance

Guidance on selecting equipment to match anticipated peak load and humidity control.

Indoor Unit Mounting Instructions

Instructions for unit leveling and providing adequate clearance for optimal airflow.

Outdoor Unit Mounting Guidelines

Guidance on unit leveling, clearance, location, and wind protection for outdoor units.

System Operating Conditions

Details the cooling and heating operating ranges for outdoor and indoor units.

Low Ambient Operation

Explains cooling operation at lower temperatures and the need for accessory kits.

Drain Connections

Covers installation of drains and the use of accessory condensate pumps.

Refrigerant and Control Information

General Refrigerant Line Sizing

Provides guidelines for line sizing, burial, insulation, and vibration isolation.

Long Line Applications

Details requirements for longer line lengths, including crankcase heaters and wind baffles.

Additional Charge Table

Lists refrigerant charge adjustments based on line length.

Wiring Overview

Explains power supply and connection details between outdoor and indoor units for different models.

Microprocessor Control System

Describes the control system functions, operating modes, and manual button operations.

Wireless Remote Control

Outlines the function and range of the wireless remote control for system operation.

Technical Data Summary

Air Throw Data

Provides air throw distances for different unit capacities at various airflow settings.

Sound Ratings

Lists sound power and sound pressure ratings for indoor and outdoor units.

Electrical Data

Details electrical specifications including voltage, amps, and fuse/breaker ratings.

Wiring Diagrams

Wiring Diagram 38 MVC009-1;40 MVC009-1

Illustrates electrical connections between outdoor and indoor units for model 38MVC009/40MVC009.

Wiring Diagram 38 MVC012-1;40 MVC012-1

Shows electrical connections for 38MVC012 and 40MVC012 indoor units.

Wiring Diagram 38 MVC012-3;40 MVC012-3

Details electrical connections for 3-phase 38MVC012 and 40MVC012 units.

Wiring Diagram 38 MVQ018-3;40 MVQ018-3

Illustrates wiring for 3-phase 38MVQ018 and 40MVQ018 units.

Wiring Diagram 38 MVQ024-3;40 MVQ024-3

Depicts wiring connections for 3-phase 38MVQ024 and 40MVQ024 units.

Wiring Diagram 38 MVQ009-1;40 MVQ009-1

Shows electrical connections for 38MVQ009 and 40MVQ009 outdoor and indoor units.

Wiring Diagram 38 MVQ012-1;40 MVQ012-1

Details the wiring for 38MVQ012 and 40MVQ012 indoor units.

Wiring Diagram 38 MVQ012-3;40 MVQ012-3

Illustrates the wiring for 3-phase 38MVQ012 and 40MVQ012 units.

Wiring Diagram 38 MVQ018-3;40 MVQ018-3

Depicts the wiring for 3-phase 38MVQ018 and 40MVQ018 units.

Wiring Diagram 38 MVQ024-3;40 MVQ024-3

Shows the electrical connections for 3-phase 38MVQ024 and 40MVQ024 units.

Indoor Unit Guide Specifications

System Description

Overview of wall-mounted fan coils matched with outdoor units for cooling or heat pump operation.

Agency Listings

Requirements for unit compliance with ARI Standards 210/240 and directory listing.

Equipment - General

Details the wall-mounted fan coil unit components including coil, fan, motor, and controls.

Equipment - Controls

Lists minimum functions for the microprocessor control system, including restart, timer, and freeze protection.

Electrical Requirements

Specifies voltage requirements for indoor fan motors and power supply from the outdoor unit.

Operating Characteristics

Lists minimum SEER and HSPF ratings required for the 40MVC, MVQ system.

Special Features (Field Installed)

Describes optional field-installed features like condensate pumps and crankcase heaters.

Outdoor Unit Guide Specifications

System Description

Overview of air-cooled split system outdoor units for cooling or heat pump applications.

Agency Listings

Specifies compliance with ANSI/ASHRAE 15, UL 1995, and salt spray testing requirements.

Equipment - General

Details the factory-assembled single-piece outdoor unit, including wiring, piping, controls, and compressor.

Equipment - Compressor

Describes the hermetic rotary compressor, its protection features, and motor specifications.

Controls and Safeties

Lists required control functions and safeties, including time delay and overload protection.

Special Features (Field Installed)

Outlines optional field-installed features like low-ambient kits and wind baffles.

Related product manuals