5) DESCRIPTION OF FUNCTIONS
(1) Timer Mode
General features
– If user changes time of ON/OFF timer during timer function execution, the timer will be
changed according to the new set time.
– The other mode changes are enabled during timer function execution.
– The maximum timer range is twenty-four hours according to the remote controller.
– If user pushes the TEST or EMERG. button during timer function execution, timer function
will be canceled.
– If unit receives the timer function signal in Test or Emergency operation, these operations
will be canceled and timer function will be operated.
OFF-Timer
– If user sets time with OFF timer, the unit will stop at the set time.
– The unit will be turned off automatically when the set time of OFF timer is reached.
UNIT ON
UNIT OFF
HOURT.S.
T.S.=USER SET TIME
ON-Timer
– When the ON timer is set, unit monitors the room temperature before 1 hour from set time to
make the room as set condition at reserved set time.
– The actual on time of unit is decided at 0 to 40 minutes earlier than reserved on time accord-
ing to the room temperature and size.
UNIT OFF
HOUR
UNIT ON
T.S.
ACTUAL ON TIME(0~40MIN)