5) DESCRIPTION OF FUNCTIONS
(1) Timer Mode
General features
If user changes time of ON/OFF timer during timer function execution, the timer will be
changed according to the new set time.
The other mode changes are enabled during timer function execution.
The maximum timer range is twenty-four hours according to the remote controller.
If user pushes the TEST or EMERG. button during timer function execution, timer function
will be canceled.
If unit receives the timer function signal in Test or Emergency operation, these operations
will be canceled and timer function will be operated.
OFF-Timer
If user sets time with OFF timer, the unit will stop at the set time.
The unit will be turned off automatically when the set time of OFF timer is reached.
UNIT ON
UNIT OFF
HOURT.S.
T.S.=USER SET TIME
ON-Timer
When the ON timer is set, unit monitors the room temperature before 1 hour from set time to
make the room as set condition at reserved set time.
The actual on time of unit is decided at 0 to 40 minutes earlier than reserved on time accord-
ing to the room temperature and size.
UNIT OFF
HOUR
UNIT ON
T.S.
ACTUAL ON TIME(0~40MIN)