21
 
INSTALLATION OF INDOOR UNITS (Cont.) 
 
INSTALLATION STEPS OF INDOOR UNIT (Cont.) 
Step (8): Passing refrigerant piping, 
electrical cords and drain hose 
of indoor unit through wall 
sleeve. 
 
•  Passing refrigerant piping lines 
through the wall sleeve is done before 
hooking the indoor unit body onto the 
top of the wall hang bracket. 
 
•  For left piping, hang the unit onto the 
top of the wall hang bracket and 
incline the unit using a tool such as a 
screw driver set between the middle 
area of body and bottom right of the 
wall hang bracket. 
 
  Connecting the piping can be done more 
easily if the unit is inclined. 
 
Warning: 
Do not supply power to the indoor unit until all 
refrigerant piping and electrical wiring to the 
outdoor unit are completed. 
 
 
Step (9): Installing the Indoor Unit Body 
  to the Wall  Mounting Bracket 
 
• Snap the marking places of the body (A, B) 
onto the hole of the bracket. 
 
 NOTES: 
• In case of removing the unit from the wall 
hang bracket after installing it onto the wall, 
remove it by pushing up the indicated marks  
( ▼) at the bottom of the body. 
 
• After installation of unit, if there is a 
significant gap between the unit and wall, 
securing 2 screws to the body and wall-
mounting bracket can adjust it. 
 
Refer to the screw hole location (C, D) in the 
Figure. 
Screw holes can be only seen after removing 
the grille frame. 
 
 
 
A  B  C  D 
340