54A
Impianto a 2 tubi / 2 pipe unit / Installation à 2 tubes
2-Leiter-Anlage / Instalación de 2 tubos / 2-pijpsysteem
Mod.
30 40
Speed
1 3 5 7, 5 10 1 3 5 7, 5 10
MIN MED MED MIN MED MED
Qv m3/h
270 345 420 520 620 375 465 550 665 770
Pc kW
1,82 2,19 2,52 2,92 3,27 2,33 2,71 3,03 3,41 3,72
Ps kW
1,30 1,59 1,85 2,17 2,48 1,69 2,00 2,27 2,61 2,89
Pl kW
0,52 0,60 0,67 0,74 0,79 0,64 0,71 0,76 0,81 0,83
Ph kW
1,83 2,24 2,63 3,11 3,57 2,40 2,85 3,26 3,76 4,20
Lw dB(A)
37 42 45 49 53 43 46 49 53 57
Pec W
6 8 11 15 20 9 12 16 22 30
Mod.
10 20
Speed
1 3 5 7, 5 10 1 3 5 7, 5 10
MIN MED MED MIN MED MED
Qv m3/h
190 240 290 355 415 260 315 375 440 510
Pc kW
1,16 1,38 1,57 1,80 1,98 1,46 1,66 1,86 2,05 2,24
Ps kW
0,85 1,03 1,19 1,39 1,56 1,09 1,27 1,45 1,63 1,81
Pl kW
0,31 0,35 0,38 0,41 0,42 0,37 0,39 0,41 0,42 0,43
Ph kW
1,26 1,53 1,78 2,09 2,35 1,63 1,90 2,18 2,46 2,74
Lw dB(A)
35 39 46 48 52 40 44 47 51 55
Pec W
6 7 9 11 15 7 9 12 16 21