172
* BACnet is a registered trademark of ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers).
Table AA — BACnet* MSV Points List
POINT DESCRIPTION POINT ACCESS UNITS
BACNET
OBJECT NAME
BACNET
ID
VALUE
RANGE
CCN POINT
EQUIVALENT
Active Occupancy control READ ONLY occ_ctrl MSV:14 0 to 6 OCC_CTRL
Alert from thermostat READ ONLY tstat_alert MSV:8 0 to 65535 THM_ALT
Analog Input IAQ Control R/W iaqancfg MSV:25 0 to 3 IAQANCFG
Backup and Restore READ ONLY bac_rest MSV:44 0 to 2
BACnet BMS baud rate READ ONLY bac_baud MSV:18 0 to 5 BAC_BAUD
BAS Protocol Select R/W bms_cfg MSV:11 0 to 2 BMS_CFG
BMS Occupancy Request R/W bms_occ MSV:12 0 to 2 BMS_OCC
Communications status R/W e0commst MSV:17 0 to 1 E0COMMST
Comp. Framework R/W sysvtype MSV:2003 0 to 2 SYSVTYPE
Cool demand Limit Level R/W cdlm_level MSV:56 0 to 3 CDMDLLEV
Fan Based Dehum Type R/W fbd_type MSV:58 0 to 2 FBD_TYPE
Filter Status Sw Channel R/W filter_channel MSV:41 0 to 5 FILTCHAN
Filter Status Swith Type R/W filt_cfg MSV:42 0 to 2 FILT_CFG
Firmware Release State READ ONLY fw_state MSV:19 0 to 2 FW_STATE
Heat demand Limit Level R/W hdlm_level MSV:57 0 to 3 HDMDLLEV
IAQ override sw channel R/W iaqo_sw_chan MSV:444 0 to 5 IAQOCHAN
IDF VFD Fault Detail READ ONLY svfdflt MSV:23 0 to 17 SVFDFLT
IDF VFD Nom Motor HP Num READ ONLY motpwr MSV:22 0 to 500 MOTPWR
IDF VFD RFI Filter R/W rfi_filter MSV:4 0 to 1 RFIFILTR
IDF VFD Switch Frequency R/W switch_freq MSV:7 0 to 10 SWTFREQ
IDF VFD Warning Detail READ ONLY vfd_warning MSV:3001 0 to 5 SVFDWAR
Indoor Fan Type Cfg R/W idftype MSV:450 0 to 2 IDFTYPE
Keep configuration R/W keepconf MSV:47 0 to 2 KEEPCONF
Linkage Occupied Request R/W lnk_occ MSV:13 0 to 2 LNK_OCC
Operation Status Color READ ONLY color MSV:9 0 to 15 COLOR
Remote Occupancy Channel R/W rmocchan MSV:46 0 to 5 RMOCCHAN
Remote Occupancy Sw Type R/W rmoc_cfg MSV:45 0 to 1 RMOC_CFG
Running Mode Operation READ ONLY sub_mode MSV:43 0 to 2 SUB_MODE
System Demand READ ONLY sys_demand_enum MSV:101 0 to 255 SYS_DMDE
System Mode READ ONLY sys_mode MSV:2002 0 to 2 SYSMODE
Test Inactivity Time Out R/W test_ito MSV:156 0 to 2 TEST_ITO
Thermostat Hardware Type R/W tstat_type MSV:5 0 to 3 STATTYPE
Type of Heat Installed R/W ht_type MSV:16 0 to 2 HEATTYPE
Unit Control Type R/W control_type MSV:2 0 to 2 CTRLTYPE
Ventilation Status READ ONLY ventstat MSV:6 0 to 9 VENTSTAT
When to Unocc Free Cool? R/W ufc_cfg MSV:24 0 to 2 UFC_CFG
APPENDIX E — BACNET POINTS LIST