EasyManua.ls Logo

Carrier 50DPE014 - Page 5

Carrier 50DPE014
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
1b
Physical
Data
50DP016,020
UNIT
SIZE
50DP016
50DP020
OPERATING
WEIGHT
(lb)
Unit
(Outdoor
Coil/Indoor
Coil)
AI/AI
Al/Cu
Cu/Cu
Roof
Curb
Economizer
Electric
Heat
1470
1550
1630
2i
1
1980
2110
2220
00
10
65
COMPRESSOR
Quantity
Oil
(oz)
Semi-Hermetic
1
160
:
6
Cylinders
2
160
ea
REFRIGERANT
Charge
(lb)
Sys
1*,
Sys
2
R-22
21.2
R-22
17.0,
17.0
REFRIGERANT
METERING
DEVICE
Upper
Circuit
Quantity...Length...ID/OD
(in.)
Lower
Circuit
Quantity...Length...ID/OD
(in.)
Capillai
6.40.
0.065/0
125
6..20.0
055/0.125
6.20
0
055/0
125
y
Tubes
13.25.0
055/0
125
13
.25
..0
055/0.125
OUTDOOR
COIL
Rows
Fins/in.
Aluminum
Copper
Total
Face
Area
(sq
ft)
Copper
Tubes,
Alumini
3
136
12.4
18.9
jm
or
Copper
Plate
Fins
4
13.6
12.4
22.2
OUTDOOR
AIR
FAN
Nominal
Cfm
Number...Diameter
(in.)
Motor
Hp
(1075
Rpm)
Propeller
Typ
12,000
2
.26
1
ie,
Direct
Drive
11,400
2.
.26
1
INDOOR
COIL
Rows
Fins/in.
Aluminum
Copper
Total
Face
Area
(sq
ft)
Copper
Tubes,
Alumini
3
143
13
1
16.5
um
or
Copper
Plate
Fins
4
14.4
13.1
17.9
INDOOR
AIR
FANf
Quantity...Size
(in.)
Nominal
Cfm
Rpm
Range
Std
Opt
Pulley
A
Pulley
B
Maximum
Allowable
Rpm
Motor
Pulley
Pitch
Diameter
(in.)
Std
Opt
Pulley
A
Pulley
B
Fan
Pulley
Pitch
Diameter
(in.)
Belt,
Quantity...Type...Length
(in.)
Speed
Change
per
Full
Turn
Std
of
Moveable
Pulley
Flange
(Rpm)
Opt
Moveable
Pulley
Max
Full
Turns
from
Closed
Position
Factory
Setting
Full
Turns
Open
Factory
Speed
Setting
(Rpm)
Std
Opt
Pulley
A
Pulley
B
Motor
Hp
(Service
Factor)
Std
Opt
Centrifuga
2
..10x10
6000
916-1186
1158-1428
1550
3
4-4
4
4
3-5
3
6.4
1.
.V...45
54
55
5
3.5
970
1240
3
{1
15)
il,
Belt
Drive
2
.12x12
7200
848
1060
1550
32
40
6.6
2
V..45
848
1060
5
(1
15)
HIGH-PRESSURE
SWITCH
Cutout
(psig)
Reset
(psig)
428
320
LOW-PRESSURE
SWITCH
(Liquid
Line)
Cutout
(psig)
Reset
(psig)
27
60
AIR
INLET
SCREENS
Economizer,
Number...Size
(in.)
2.
.20x25x1
1...20x20x1
INDOOR
AIR
FILTERS
(Type)
Number...Size
(in.)
10%
efficient
D
2
20x20x2
3.
16x20x2
2.
.16x25x2
isposable
Fiberglass
4
20x20x2
4..
16x20x2
'System
1
consists
of
upper
portion
of
outdoor
coil
and
lower
portion
of
indoor
coil,
except
for
size
020
which
is
intertwined
|016
unit
has
adjustable
standard
and
alternate
drives
The
020
unit
does
not
have
an
alternate
drive,
but
has
2
non-adjustable
pulleys
Pulley
A
is
installed
in
unit,
pulley
B
is
shipped
with
unit
5

Related product manuals