COMPRESDORBIOWER,E_ECTRIC_EAT_
& _[ECIRIC ACCESS \
\
\
__\
.................................... 11231
144 22} ........................................_\\
LEFT SIDE VIEW
TOP VIEW
40, 0
fl983}
C01L I ...........
_137
[4 €3]
88 3
[348]
DIMENSIONS IN [1 ARE IN !NCHES
SUPPLY "
DUCT
3 3 52 --,-43_1 _ 4
113 831 [3 67] { 3 83
REAR VIEW
445 [!75] OIA KO
POW#R INTRY
22 ' [088] OlA HOLE-
CONTROL ENTRY
8?1
13 43]
1222
[4 81]
__A ,,
_%
'4 I I I
[ODO}
RIGHT SIDE VIEW
REQUIRED CLEARANCE TO COMBUSTIBLE MATE
INCHES [ram]
TOP OF UNIT ................................................................................... 14.00 [355.6]
DUCT SIDE OF UNIT ......................................................................... 2.00 [50.8]
SIDE OPPOSITE DUCTS ................................................................ 14.00 [355.6]
BOTI-OM OF UNIT ............................................................................. 0.50 [12.7]
ELECTRIC HEAT PANEL ................................................................. 36.00 [914.4]
NEC. REQUIRED CLEARANCES.
INCHES [ram]
BETWEEN UNITS, POWER ENTRY SIDE .................................... 42.00 [1066.8]
UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE .38.00 [914.0]
UNIT AND BLOCK OR CONCRETE WALLS AND OTHER
GROUNDED SURFACES, POWER ENTRY SIDE ......................... 42.00 [1086.8]
REQUIRED CLEARANCE FOR OPERATION AND SERVICING
INCHES [ram]
EVAR COIL ACCESS SIDE ............................................................ 36.00 [914.0]
POWER ENTRY SIDE .................................................................... 36.00 [914.0]
(EXCEPT FOR NEC REQUIREMENTS)
UNIT TOP ....................................................................................... 48.00 [1219.2]
SIDE OPPOSITE DUCTS .............................................................. 36.00 [914.0]
DUCT PANEL ................................................................................. 12.00 [304.8] *
*MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN 304.8 [12.00] FROM
WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE.
C99006
UNiT
50GS048
50GS060
50GX042
50GX048
50GX060
ELECTRICAL CHARACTERISTICS
208/230-3-60, 480-3-60
208/230-3-60, 480-3-60
208/230-3-60, 480-3-60
208/230-3-60, 480-3-60
208/230-3-60, 480-3-60
UNIT WEIGHT
lb. kg
324 145
389 178
321 148
328 148
399 181
UNiT HEIGHT
IN. (MM)
"A"
38,98 (990,2)
38,98 (990,2)
38,98 (990,2)
38,98 (990,2)
42,98 (1091,1)
CENTER OF GRAVITY
IN.(MM)
X
20.0 (508.0)
19.0 (482.8)
20.5 (520.7)
19.5 (495.3)
20.5 (520.7)
Y Z
17.0 (432.0) 17.0 (432.0)
18.0 (406.0) 17.0 (432.0)
16.75 (425.5) 16.6 (421.6)
17.8 (447.8) 18.0 (457.2)
18.2 (412.8) 17.6 (447.0)
Fig. 3-- 50GS048-060 and 50GX042-060 Unit Dimensions