14
50ZH
Performance data (cont)
COOLING CAPACITY
See page 15 for cooling notes.
HEATING CAPACITY
50ZH060 (5 TONS)
Temp (F)
Air Ent
Outdoor
coil (edb)
Evaporator Air—CFM/BF
1750/0.08 2000/0.08 2250/0.09
Evaporator Air — Ewb (F)
72 67 63* 62 72 67 63* 62 72 67 63* 62
85
TC 65.7 59.9 55.5 54.4 66.4 60.8 56.5 55.7 67.3 61.7 57.4 57.4
SHC 33.7 43.4 50.8 52.5 35.2 46.5 54.4 55.7 36.8 49.4 57.3 57.4
kW 5.55 5.45 5.35 5.33 5.67 5.58 5.48 5.47 5.82 5.71 5.61 5.62
95
TC 63.1 55.0 52.8 51.8 64.1 58.1 53.7 53.5 64.7 58.8 55.3 55.0
SHC 32.9 41.9 49.6 51.1 34.5 45.4 53.1 53.4 36.3 48.3 55.2 55.0
kW 5.94 5.85 5.74 5.72 6.08 5.98 5.87 5.88 6.21 6.09 6.02 6.03
105
TC 60.2 53.6 49.9 49.3 61.0 54.9 51.2 51.1 61.7 55.7 52.7 52.6
SHC 31.9 40.8 48.3 49.3 33.6 44.3 51.1 51.1 35.3 47.2 52.7 52.6
kW 6.37 6.28 6.18 6.16 6.50 6.40 6.32 6.33 6.64 6.52 6.47 6.48
115
TC 57.3 51.2 47.1 46.7 58.0 51.8 48.7 48.7 58.6 52.6 50.1 50.2
SHC 30.9 40.1 47.0 46.7 32.7 43.1 48.7 48.7 34.3 46.1 50.1 50.1
kW 6.80 6.71 6.61 6.60 6.92 6.83 6.77 6.78 7.07 6.95 6.92 6.93
50ZH060
Temp (F)
Air Ent
Indoor
Coil
Indoor
Air CFM
(Std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
-100 1017203040475060
60
1800
Cap.
15.1
13.9 19.4 17.8 24.3 22.3 28.6 26.1 30.8 27.9 37.7 33.0 45.8 45.8 53.5 53.5 56.3 56.3 68.1 68.1
kW
3.48 3.64 3.82
3.97 4.05
4.28 4.56 4.79
4.88 5.26
2000
Cap.
15.1
13.9 19.4 17.8 24.6 22.6 28.8 26.3 30.9 28.1 38.0 33.3 46.3 46.3 53.9 53.9 56.5 56.5 68.7 68.7
kW
3.53 3.69 3.87 4.01 4.08 4.31 4.57 4.80 4.88 5.24
2250
Cap.
15.1
13.9 19.8 18.2 25.2 23.1 29.3 26.8 31.5 28.5 28.7 33.9l 47.1 47.1 54.7 54.7 57.3 57.3 69.8 69.8
kW
3.60 3.76 3.94 4.08 4.14 4.36 4.62 4.83 4.91 5.26
70
1800
Cap.
14.4
13.2 18.7 17.2 23.7 21.8 28.0 25.5 30.2 27.4 37.0 32.4 44.9 44.9 52.5 52.5 55.2 55.2 66.7 66.7
kW
3.71 3.90 4.10
4.25 4.33
4.59 4.88 5.13
5.23 5.63
2000
Cap.
14.3
13.2 18.7 17.2 24.0 22.0 28.3 25.8 30.4 27.5 37.3 32.7 45.3 45.3 52.8 52.8 55.4 55.4 67.3 67.3
kW
3.76 3.94 4.14 4.29 4.36 4.61 4.89 5.12 5.21 5.60
2250
Cap.
14.3
13.2 19.0 17.5 24.2 22.2 28.7 26.2 30.8 28.0 37.9 33.2 46.1 46.1 53.6 53.6 56.1 56.1 68.3 68.3
kW
3.83 4.01 4.19 4.34 4.42 4.66 4.92 5.15 5.23 5.60
80
1800
Cap.
13.5
12.4 17.8 16.4 22.9 21.1 27.2 24.8 29.3 26.6 36.2 31.7 43.9 43.9 51.4 51.4 54.2 54.2 65.3 65.3
kW
3.97 4.18 4.40
4.57 4.65
4.93 5.24 5.51
5.62 6.04
2000
Cap.
13.5
12.4 17.8 16.4 23.2 21.3 27.5 25.1 29.6 26.8 36.6 32.0 44.4 44.4 51.8 51.8 54.4 54.4 65.9 65.9
kW
4.02 4.22 4.43 4.60 4.67 4.94 5.24 5.49 5.59 5.99
2250
Cap.
13.5
12.4 18.1 16.7 23.6 21.7 27.9 25.5 30.0 27.2 37.1 32.5 44.9 44.9 52.4 52.4 54.9 54.9 66.7 66.7
kW
4.08 4.28 4.49 4.64 4.72 4.98 5.26 5.50 5.59 5.98
LEGEND
C
ap. — Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)
d
b — Dry Bulb
kW Total Power Input (Includes Compressor Motor Power Input
Outdoor-Fan Motor Input, and Indoor-Fan Motor Input)
rh — Relative Humidity
NOTES:
1. indicates integrated ratings
2. Integrated capacity is maximum (instantaneous) capacity less the
effect of frost on the outdoor coil and the heat required to defrost it.