Do you have a question about the Carrier 50ZH Series and is the answer not in the manual?
Series | 50ZH |
---|---|
Type | Heat Pump |
Manufacturer | Carrier |
Refrigerant | R-410A |
Voltage Options | 208/230V |
Phases | 1 |
Details on lightweight, compact design and jobsite planning for the 50ZH units.
Highlights the redesigned fan blade for improved sound reduction.
Explains the split-top design for easy access during installation and maintenance.
Features a composite material base for rust prevention and improved drainage.
Describes the watertight and corrosion-resistant steel cabinet for longevity.
Details the hermetically sealed scroll compressors with internal protection.
Covers computer-designed coils for optimum heat transfer and cooling efficiency.
Explains the time/temperature-based defrost cycles for maintaining unit efficiency.
Describes available drop-in style cartridge electric heaters with single-point connections.
Mentions starter collars provided for easy connection to structure ductwork.
Highlights direct-drive motors and robust refrigerant system components.
Explains the coding system used for 50ZH unit model numbers.
Presents SEER, HSPF, COP, and sound ratings for various 50ZH unit sizes.
Details operating weight, compressor type, and refrigerant charge for each unit size.
Provides specifications for outdoor coil, fan motor, and related components.
Lists specifications for evaporator coil, fan motor, and related components.
Specifies connecting duct sizes and field-supplied return air filter dimensions.
Describes accessories like Low Ambient Control, Controls Upgrade Kit, and Crankcase Heater.
Details the usage of accessory electric heaters with specific unit sizes.
Provides factors to adjust electric heater capacity based on voltage distribution.
Illustrates the unit's physical dimensions and layout.
Specifies required clearances for installation, operation, and servicing.
Provides unit weight and center of gravity information for the 50ZH030 model.
Illustrates the physical dimensions and layout for 50ZH036 and 50ZH048 models.
Specifies required clearances for installation, operation, and servicing for these models.
Provides unit weight and center of gravity for 50ZH036 and 50ZH048 models.
Illustrates the physical dimensions and layout for the 50ZH060 model.
Specifies required clearances for installation, operation, and servicing for this model.
Provides unit weight and center of gravity information for the 50ZH060 model.
Steps to determine cooling and heating needs based on design conditions.
Guidance on selecting the appropriate unit based on cooling capacity requirements.
Procedure for selecting the correct electric heat capacity and units.
Calculates total static pressure and fan speed requirements for optimal performance.
Presents cooling capacity (TC) and sensible heat capacity (SHC) at various conditions.
Provides heating capacity (Cap.) and power input (kW) at different temperature and airflow conditions.
Presents cooling capacity (TC) and sensible heat capacity (SHC) at various conditions.
Provides heating capacity (Cap.) and power input (kW) at different temperature and airflow conditions.
Presents cooling capacity (TC) and sensible heat capacity (SHC) at various conditions.
Provides heating capacity (Cap.) and power input (kW) at different temperature and airflow conditions.
Presents cooling capacity (TC) and sensible heat capacity (SHC) at various conditions.
Provides heating capacity (Cap.) and power input (kW) at different temperature and airflow conditions.
Presents cooling capacity (TC) and sensible heat capacity (SHC) at various conditions.
Provides heating capacity (Cap.) and power input (kW) at different temperature and airflow conditions.
Details pressure drop across the wet coil for different unit sizes and airflows.
Provides pressure drop data for filters based on size and airflow.
Lists pressure drop for accessory electric heaters at various airflow rates.
Presents CFM and Watt data for various external static pressures and motor speeds.
Details voltage range, compressor specs, FLA, MCA, and max fuse/breaker ratings.
Provides FLA, MCA, and max fuse/breaker ratings for electric heat options.
Illustrates the physical layout and electrical connections for the unit.
Explains symbols and provides important notes for wiring installation.
Details the electrical connections for 460-3-60 voltage units.
Shows the wiring connections for accessory electric heaters.
Explains how to calculate and assess voltage imbalance in 3-phase supply.
Describes the unit's operational sequence during cooling, heating, and defrost modes.
Explains the time and temperature-based control for the defrost cycle.
Illustrates a typical installation setup for the heat pump unit.
Specifies the need for a 2-inch condensate trap.
Defines maximum and minimum cooling airflow requirements for the units.
Outlines minimum ambient and maximum operating temperatures for cooling.
Details system overview, quality assurance, and compliance with industry standards.
Provides guidelines for proper delivery, storage, and handling of the unit.
Describes the unit enclosure, basepan, insulation, and serviceability features.
Details specifications for fans, compressor type, and coil construction.
Covers refrigerant components, safeties, operating characteristics, and motor details.
Details electric heater options, safety controls, and thermostat capabilities.
Lists optional coil types, economizer functions, and low ambient operation packages.
Covers crankcase heater function, duct transitions, and other installation accessories.