EasyManua.ls Logo

Carrier 58CTX - Page 13

Carrier 58CTX
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Table 4 Opening dimensions -- In. (mm)
FURNACE
CASING
WIDTH
APPLICATION
PLENUM OPENING FLOOR OPENING
A B C D
14–3/16
(376)
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
12--- 11/16
(322)
21--- 5/8
(549)
13--- 5/16
(338)
22--- 1/4
(565)
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
12--- 9/16
(319)
19
(483)
13--- 3/16
(335)
19--- 5/8
(498)
Downflow applications on combustible flooring (KGASB sub-
base required)
11--- 13/16
(284)
19
(483)
13--- 7/16
(341)
20--- 5/8
(600)
Downflow Applications on Combustible Flooring with CNPV,
CNRV, CAR, or CAP Coil Assembly or KCAKC coil box
(KGASB subbase not required)
12--- 5/16
(319)
19
(483)
13--- 5/16
(338)
20
(508)
17–1/2
(445)
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
16
(406)
21--- 5/8
(549)
16--- 5/8
(422)
22--- 1/4
(565)
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
15--- 7/8
(403)
19
(483)
16--- 1/2
(419)
19--- 5/8
(498)
Downflow applications on combustible flooring (KGASB sub-
base required)
15--- 1/8
(384)
19
(483)
16--- 3/4
(425)
20--- 5/8
(600)
Downflow Applications on Combustible Flooring with CNPV,
CNRV, CAR, or CAP Coil Assembly or KCAKC coil box
(KGASB subbase not required)
15--- 1/2
(394)
19
(483)
16--- 1/2
(419)
20
(508)
21
(533)
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
19--- 1/2
(495)
21--- 5/8
(549)
20--- 1/8
(511)
22--- 1/4
(565)
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
19--- 3/8
(492)
19
(483)
20
(508)
19--- 5/8
(498)
Downflow applications on combustible flooring (KGASB sub-
base required)
18--- 5/8
(473)
19
(483)
20--- 1/4
(514)
20--- 5/8
(600)
Downflow Applications on Combustible Flooring with CNPV,
CNRV, CAR, or CAP Coil Assembly or KCAKC coil box
(KGASB subbase not required)
19
(483)
19
(483)
20
(508)
20
(508)
24--- 1/2
(622)
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
23
(584)
21--- 1/8
(537)
23--- 5/8
(600)
22--- 1/4
(565)
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
22--- 7/8
(581)
19
(483)
23--- 1/2
(597)
19--- 5/8
(498)
Downflow applications on Combustible flooring (KGASB sub-
base required)
22--- 1/8
(562)
19
(483)
23--- 3/4
(603)
20--- 5/8
(600)
Downflow Applications on Combustible Flooring with CNPV,
CNRV, CAR, or CAP Coil Assembly or KCAKC coil box
(KGASB subbase not required)
22--- 1/2
(572)
19
(483)
23--- 1/2
(597)
20
(508)
UPFLOW DOWNFLOW HORIZONTAL
YES
NO
NO
YES
YES
YES
NO
120
MIN
YES
120
MIN
YES
120
MIN
90
90
A02020
Fig. 14 -- Duct Flanges
58CT

Other manuals for Carrier 58CTX