Carrier 58GP - Manual Ignition (Continuous) Pilot

Carrier 58GP
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
in.
the
open
position
when
the
thermostat
is
calling
for
heat.”
See
Fig.
6.
IF
THE
DAMPER
IS
NOT
OPEN,
shut
down
the
furnace
and
call
your
dealer
for
service.
MANUAL
IGNITION
(CONTINUOUS)
PILOT
NOTE:
Your
gas
valve
may
be
different
from
that
pictured.
Refer
to
the
lighting
instructions
label
affixed
to
your
fur¬
nace
blower
access
door
(See
Figs.
1
and
2
for
door
identifi¬
cation)
for
the
correct
picture.
1.
Set
your
room
thermostat
to
its
lowest
temperature
setting.
See
Fig.
7.
2.
Close
the
external
manual
gas
valve.
See
Fig.
8.
3.
Turn
OFF
the
electrical
supply
to
your
furnace.
See
Fig.
9.
Refer
to
the
lighting
instruction
label
affixed
to
the
furnace
blower
access
door.
Depress
the
button
or
knob
and
hold
it
down.
The
pilot
will
light.
Remove
and
extinguish
the
match
while
continuing
to
hold
the
button
or
knob
down
for
at
least
60
seconds.
Then,
release.
The
pilot
will
remain
lit.
NOTE'
If
the
pilot
does
not
remain
lit,
repeat
steps
5
through
8;
however,
hold
the
button
down
for
a
longer
period
of
time
(at
least
90
seconds).
If
the
pilot
flame
is
extinguished
after
this
second
attempt,
the
thermocouple
should
be
checked
for
a
possible
malfunction.
Call
your
dealer
for
service.
4.
Remove
the
access
door(s)
from
your
furnace.
Lift
up
and
out
at
the
bottom.
See
Fig.
10
for
upflow
and
Fig.
9.
A
fter
the
pilot
flame
is
established,
turn
the
control
knob
on
the
gas
valve
to
the
ON
position.
10.
Replace
the
access
door.
Insert
door
end
into
the
fur¬
nace,
push
the
door
in
and
down.
See
Fig.
15
or
16.
On
downflow
furnaces,
remove
the
blower
access
door,
install
the
control
access
door,
then
reinstall
the
blower
access
door.
11.
Turn
on
the
electrical
supply
to
the
furnace.
12.
Adjust
the
room
thermostat
to
a
setting
slightly
above
___
titUI
on+Amsif.irflllv
sicmal
the
11
for
downflow
furnaces.
NOTE:
The
blower
access
door
must
be
installed
to
permit
furnace
operation.
On
downflow
furnaces,
the
blower
access
door
must
be
removed
before
the
control
access
door
is
removed,
then
reinstalled.
5.
Turn
the
control
knob
on
the
internal
gas
valve
clock¬
wise
to
the
indicated
OFF
position.
Wait
5
minutes
for
any
expelled
gas
to
dissipate.
See
Fig.
12.
6.
After
waiting
5
minutes,
open
the
external
manual
gas
valve.
See
Fig.
13.
7.
Turn
the
control
knob
on
the
internal
gas
valve
to
the
PILOT
position.
8.
Place
a
lighted
match
or
other
suitable
source
of
flame
near
the
top
of
the
pilot.
See
Fig.
14.
5