SAFETY CONSIDERATIONS
Recognize safety information. This is the safety-alert sym-
bol z2x. When you see this symbol on the furnace and in
instrucfions or manuals, be alert to the potential for personal
injury.
Understand the signal words--DANGER, WARNING,
CAUTION and NOTE. DANGER, WARNING and
CAUTION are used with the safety-alert symbol. DANGER
identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies hazards which
could result in personal injury or death. CAUTION is used
m identify unsafe practices which would result in minor per-
sonal injury or product and prop-erty damage. NOTE is used
to highlight suggestions which will result in enhanced instal-
lafion, reliability or operation.
To minimize the possibility of serious personal injury, fire,
furnace damage, or improper operation; carefully follow
these safety rules:
• Your gas furnace uses air from outside the home for com-
bustion and vents flue gas to the outdoors. It is not to be
installed using indoor air for combustion. The vent and air-
intake pipes must terminate outside the structure and must
not be obstructed in any way. Do not block or obstruct air
openings on furnace or spaces around the furnace.
V!I gll-'1-'l [e]
5
• Keep the area around your furnace clear and flee of COln-
bustible materials, gasoline, and other flammable liquids and
vapors.
• Do not cover the furnace, store trash or debris near it, or
in any way block the flow of fiesh air to the unit.
• A tunmce installed in an attic or other insulated space must
be kept fiee and clear of insulating material. Examine the fur-
nace area when the funmce is installed or when insulation is
added. Some materials may be combustible.
This furnace contains SAFETY DEVICES which must be
MANUALLY RESET. If the furnace is left unattended for
an extended period of time, have it checked periodically for
proper operation. This precaution will prevent problems
associated with no heat, such as frozen water pipes, etc. See
"Before You Request a Service Call" section in this manual.
Fire Hazard! Failure to keep insulation clear of
furnace could result in fire, personal injury/death
or property damage.
Do not keep combustible materials, gasoline, and
other flammable liquids or vapors around your
furnace. Failure to follow this warning could result
in fire, personal injury/death or property damage.
For proper and safe operation the furnace needs
air for combustion and ventilation. Do not block
or obstruct the openings on the furnace, air
openings to the area in which the furnace is in-
stalled, and the space around the furnace. Failure
to follow this warning could result in fire, personal
injury/death or property damage.
BEFORE STARTING YOUR FURNACE
Examine the furnace installation to determine that:
1. All flue gas carrying areas external to the funmce
(i.e. chimney, vent connector) are clear and tree of
obstruction s.
2. The vent connector is in place, slopes upward and is phys-
ically sound without holes or excessive corrosion.
3. The return-air duct connection(s) is physically sound, is
sealed to the funmce casing, and terminates outside the
space containing the furnace.
4. The physical support of the funmce is sound without sag-
ging cracks, gaps, etc. around the base.
5. There are no obvious signs of deterioration of the furnace.
6. The pilot and burner flames are in good adjustment (by
comparison with pictorial sketches or drawings of the
main burner flame and, if applicable, the pilot burner
flame).
6
4