Do you have a question about the Carrier 58MVP080 and is the answer not in the manual?
Minimum required distances from furnace to combustible materials for safe operation.
Procedures to protect electronic components from static discharge damage during installation.
Details for installing the furnace in an upflow configuration, blower below.
Instructions for installing the furnace in a downflow configuration, blower above.
Guidance for installing the furnace in horizontal left or right discharge orientations.
Guidelines for selecting a suitable indoor location for the furnace.
Precautions and requirements for installing the furnace in garages or other hazardous areas.
Procedure for installing optional leveling legs on the furnace base.
Specific instructions for supporting the furnace when installed in a horizontal orientation.
Standards and guidelines for designing and installing air duct systems.
Information on locating and installing air filters within the furnace or external cabinets.
Instructions for making the main power connections to the furnace.
Details on connecting thermostat and control wiring to the 24-v terminal block.
Guidelines for installing and sizing combustion air and vent pipes.
Requirements for terminating vent and combustion air pipes outside the structure.
Methods to protect condensate trap and lines from freezing, including heat tape.
Describes operation during various heating cycles, including stages and emergency heat.
Explains furnace operation when connected to cooling or heat pump systems.
Guide to setting internal switches for specific furnace configurations and accessories.
Procedure for adjusting gas input rate based on altitude and gas properties.
Method for measuring and ensuring proper air temperature rise across the heat exchanger.
Procedure to test the primary limit control for proper overheat shutoff function.
Steps to verify the operation of draft inducer pressure switches.
Minimum required distances from furnace to combustible materials for safe operation.
Procedures to protect electronic components from static discharge damage during installation.
Details for installing the furnace in an upflow configuration, blower below.
Instructions for installing the furnace in a downflow configuration, blower above.
Guidance for installing the furnace in horizontal left or right discharge orientations.
Guidelines for selecting a suitable indoor location for the furnace.
Precautions and requirements for installing the furnace in garages or other hazardous areas.
Procedure for installing optional leveling legs on the furnace base.
Specific instructions for supporting the furnace when installed in a horizontal orientation.
Standards and guidelines for designing and installing air duct systems.
Information on locating and installing air filters within the furnace or external cabinets.
Instructions for making the main power connections to the furnace.
Details on connecting thermostat and control wiring to the 24-v terminal block.
Guidelines for installing and sizing combustion air and vent pipes.
Requirements for terminating vent and combustion air pipes outside the structure.
Methods to protect condensate trap and lines from freezing, including heat tape.
Describes operation during various heating cycles, including stages and emergency heat.
Explains furnace operation when connected to cooling or heat pump systems.
Guide to setting internal switches for specific furnace configurations and accessories.
Procedure for adjusting gas input rate based on altitude and gas properties.
Method for measuring and ensuring proper air temperature rise across the heat exchanger.
Procedure to test the primary limit control for proper overheat shutoff function.
Steps to verify the operation of draft inducer pressure switches.
| Model | 58MVP080 |
|---|---|
| Blower Motor | Variable Speed |
| Fuel Type | Natural Gas |
| Warranty | 10-Year Parts Limited Warranty |
| Stages | Two-Stage |
| Ignition Type | Hot Surface Ignition |
| Heating Capacity | 80, 000 BTU/h |
| Heat Exchanger Warranty | Lifetime |












Loading...