4-Way Multipoise Direct-Vent
Variable-Capacity Condensing Gas Furnace
Installation, Start-Up, and Operating Instructions
For Sizes 040—120, Series 140 and 150
This symbol indicates a change since the last issue.
Index Page
DIMENSIONAL DRAWING........................................................3
SAFETY CONSIDERATIONS.....................................................2
Clearances to Combustibles......................................................4
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS........2
INTRODUCTION.......................................................................2-4
APPLICATIONS ......................................................................5-11
General ......................................................................................5
Upflow Applications..............................................................5-7
Downflow Applications.........................................................7-8
Horizontal Left (Supply-Air Discharge) Applications.......8-10
Horizontal Right (Supply-Air Discharge) Applications...10-11
LOCATION ............................................................................11-13
General...............................................................................11-12
Low-Fire Only Installation.....................................................13
Furnace Location Relative to Cooling Equipment ................13
Hazardous Locations...............................................................13
INSTALLATION....................................................................13-14
Leveling Legs (If Desired).....................................................13
Installation In Upflow or Downflow Applications ..........14-15
Installation In Horizontal Applications..................................14
AIR DUCTS............................................................................14-18
General Requirements.............................................................14
Ductwork Acoustical Treatment.............................................14
Supply-Air Connections..........................................................14
Return-Air Connections..........................................................14
Filter Arrangement ............................................................16-17
Bottom Closure Panel.............................................................17
Gas Piping..........................................................................17-18
ELECTRICAL CONNECTIONS...........................................18-22
115-v Wiring......................................................................18-19
24-v Wiring.............................................................................19
Accessories ........................................................................21-22
DIRECT VENTING ...............................................................22-31
Removal of Existing Furnaces from
Common Vent Systems.....................................................23
Combustion-Air and Vent Piping...........................................23
Concentric Vent and Combustion-Air Termination
Kit Installation..............................................................28-31
Multiventing and Vent Terminations.....................................31
CONDENSATE DRAIN ........................................................31-33
General...............................................................................31-32
Application..............................................................................31
Condensate Drain Protection..................................................31
SEQUENCE OF OPERATION..............................................33-36
Self-Test Mode........................................................................33
Heating Mode..........................................................................33
Heating Mode—Two Stage....................................................34
Emergency Heat Mode...........................................................34
Cooling Mode .........................................................................34
Heat Pump Mode...............................................................34-35
Continuous Fan Mode.......................................................35-36
Component Test......................................................................36
Bypass Humidifier Mode........................................................36
Dehumidification Mode..........................................................36
Zone Mode..............................................................................36
START-UP PROCEDURES ..................................................36-45
General ....................................................................................36
Select Setup Switch Positions ................................................37
Prime Condensate Trap With Water......................................37
Purge Gas Lines......................................................................38
Adjustments .......................................................................38-45
Set Gas Input Rate ............................................................38-44
Set Temperature Rise..............................................................44
A93040
NOTE: Read the entire instruction
manual before starting the installation.
ama
CERTIFIED
As an ENERGY STAR®
Partner, Carrier Corpora-
tion has determined that
this product meets the EN-
ERGY STAR® guidelines
for energy efficiency.
REGISTERED QUALITY SYSTEM
Fig. 1Multipoise Orientations
A93041
UPFLOW
DOWNFLOW
HORIZONTAL
LEFT
AIRFLOW
AIRFLOW
AIRFLOW
AIRFLOW
HORIZONTAL
RIGHT
Visit www.carrier.com
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 6a 8a
PC 101 Catalog No. 535-80021 Printed in U.S.A. Form 58MVP-11SI Pg 1 2-01 Replaces: 58MVP-10SI
Question and Answer IconNeed help?

Do you have a question about the Carrier 58MVP060 and is the answer not in the manual?

Carrier 58MVP060 Specifications

General IconGeneral
Model58MVP060
TypeGas Furnace
Heating Capacity60, 000 BTU/h
AFUEUp to 96%
Blower MotorVariable Speed
Stages of HeatTwo-Stage
Fuel TypeNatural Gas
Warranty20-Year Heat Exchanger, 5-Year Parts
Output BTU/h60, 000
EfficiencyUp to 96% AFUE
Vent TypeDirect Vent
Ignition TypeHot Surface Ignition
Heat Exchanger MaterialStainless Steel
Stages2

Summary

SAFETY CONSIDERATIONS

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

Steps to protect sensitive electronic components from static discharge damage.

INSTALLATION

Leveling Legs (If Desired)

Hazardous Locations

Safety precautions for installing the furnace in potentially hazardous environments like garages.

AIR DUCTS

Gas Piping

ELECTRICAL CONNECTIONS

DIRECT VENTING

Combustion-Air and Vent Piping

Requirements for installing combustion air and vent pipes, including material and termination.

CONDENSATE DRAIN

SEQUENCE OF OPERATION

Heating Mode

Detailed steps of the furnace's operation during various heating cycles and stages.

Cooling Mode

Operational sequence for the furnace when controlled for cooling applications.

Emergency Heat Mode

Operation sequence when the furnace is set to emergency heat, bypassing standard controls.

Continuous Fan Mode

How the furnace operates when the fan is set to run continuously for air circulation.

START-UP PROCEDURES

SET GAS INPUT RATE

Critical steps to adjust and verify the furnace's gas input rate based on altitude and gas properties.

SET TEMPERATURE RISE

Procedure to measure and set the temperature rise within specified limits for efficient operation.

CHECK SAFETY CONTROLS

SET THERMOSTAT HEAT ANTICIPATOR

Related product manuals