6
THE BLOWER IS LOCATED
TO THE RIGHT OF THE
BURNER SECTION, AND
AIR CONDITIONED AIR IS
DISCHARGED TO THE LEFT.
THE BLOWER IS
LOCATED BELOW THE
BURNER SECTION, AND
CONDITIONED AIR IS
DISCHARGED UPWARD.
THE BLOWER IS
LOCATED ABOVE THE
BURNER SECTION, AND
CONDITIONED AIR IS
DISCHARGED DOWNWARD
THE BLOWER IS
LOCATED TO THE LEFT
OF THE BURNER SECTION,
AND CONDITIONED AIR IS
DISCHARGED TO THE RIGHT.
A02097
Fig. 4 --- Multipoise Orientations
TABLE 1—DIMENSIONS (IN.)
FURNACE SIZE A
CABINET WIDTH
D
SUPPLY ---AIR
WIDTH (IN.)
E
RETURN---AIR
WIDTH (IN.)
F
C.L. TOP AND
BOTTOM FLUE
COLLAR (IN.)
FLUE
COLLAR*
(IN.)
SHIP WT (LB)
045---08/024045 14---3/16 12---9/16 12---11/16 9---5/16 4 104
045---12/036045 14---3/16 12---9/16 12---11/16 9---5/16 4 107
070---08/024070 14---3/16 12---9/16 12---11/16 9---5/16 4 111
070---12/036070 14---3/16 12---9/16 12---11/16 9---5/16 4 115
070---16/048070 17---1/2 15---7/8 16 11---9/16 4 126
090---14/042090 17---1/2 15---7/8 16 11---9/16 4 127
090---16/048090 21 19---3/8 19---1/2 13---5/16 4 140
090---20/060090 21 19---3/8 19---1/2 13---5/16 4 146
110---12/036110 17---1/2 15---7/8 16 11---9/16 4 135
110---16/048110 21 19---3/8 19---1/2 13---5/16 4 146
110---22/066110 21 19---3/8 19---1/2 13---5/16 4 152
135---16/048135 21 19---3/8 19---1/2 13---5/16 4 149
135---22/066135 24---1/2 22---7/8 23 15---1/16 4 163
155---20/060155 24---1/2 22---7/8 23 15---1/16 4 170
* 5 --- i n . o r 6 --- i n . v e n t c o n n e c t o r m a y b e r e q u ir e d i n s o m e c a s e s .
5. Use this procedure for installed and uninstalled
(ungrounded) furnaces.
6. Before removing a new control from its container,
discharge your body’s electrostatic charge to ground to
protect the control from damage. If the control is to be
installed in a furnace, follow items 1 through 4 before
bringing the control or yourself in contact with the
furnace. Put all used and new controls into containers
before touching ungrounded objects.
7. An ESD service kit (available from commercial sources)
mayalsobeusedtopreventESDdamage.
LOCATION
GENERAL
This multipoise furnace is shipped in packaged configuration.
Some assembly and modifications are required when used in any
of the four applications shown in Fig. 4.
This furnace must:
S be installed so the electrical components are protected
from water.
S not be installed directly on any combustible material
other than wood flooring (refer to SAFETY
CONSIDERATIONS).
S be located as close to the chimney or vent and attached
to an air distribution system. Refer to Air Ducts section.
S be provided ample space for servicing and cleaning.
Always comply with minimum fire protection
clearances shown on the furnace clearance to
combustible label.