Remove plug from
collector box.
DO NOT DISCARD.
If alternate vent position
is required, loosen clamp
on inlet of vent elbow.
Remove trap from
collector box.
Unconverted Factory Trap Configuration
As Viewed in the Horizontal Right Orientation
Attach condensate
trap with screw to
collector box.
Install plug in
open port on
collector box.
Slide relief tube in stand-offs
to adjust length.
Vent elbow shown in alternate
orientation. Tighten clamp on
inlet to vent elbow 15 lb.-in.
Align trap over middle and
right-hand post on collector box.
Horizontal Right Trap Configuration
A11402
Fig. 10 -- Horizontal Right Trap Configuration