EasyManua.ls Logo

Carrier Atmosphera 42EM series User Manual

Carrier Atmosphera 42EM series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
42EM
Ducted Fan Coil Unit
Selection manual
Supply
Moduboot

Other manuals for Carrier Atmosphera 42EM series

Question and Answer IconNeed help?

Do you have a question about the Carrier Atmosphera 42EM series and is the answer not in the manual?

Carrier Atmosphera 42EM series Specifications

General IconGeneral
BrandCarrier
ModelAtmosphera 42EM series
CategoryAir Conditioner
LanguageEnglish

Summary

1 - Introduction

1.1 Comfort Features

Discusses comfort provision via Carrier numeric controller.

1.2 Air Quality Considerations

Covers fresh air and filtration for improved indoor air.

1.3 Carrier Quality Commitment

Explains the company's philosophy on product conception and quality.

2 - Product Features

2.1 General Design Aspects

Highlights configuration flexibility, low noise, and compact design.

2.2 Unit Configuration Options

Details various unit arrangements and duct connection options.

2.3 Operating Limits and Environment

Specifies conditions for cooling, heating, and environmental operation.

2.4 Physical and Electrical Data

Provides technical specifications for unit dimensions and electrical properties.

2.5 Dimensional Drawings Overview

Illustrates the physical dimensions and layouts of the units.

Recommended Coil Water Quality

Details requirements for water treatment and quality in the water circuit.

3 - Safety Considerations

3.1 General Installation Safety

General precautions for installation, commissioning, and servicing.

3.2 Electrical Safety Precautions

Safety measures related to electrical components and qualified personnel.

3.3 Installation Recommendations

Guidelines for safe installation, including over-voltage protection and wiring.

3.4 Regulatory Conformity

Statement of compliance with electromagnetic compatibility and low-voltage directives.

4 - Main Components

4.1 Fresh Air Controller Functionality

Explains constant and variable fresh air flow control options.

4.2 Filter and Access Details

Details the unit's filter type, efficiency, and access methods.

4.3 Water Coil Specifications

Describes the water coil construction, connections, and available types.

4.4 Condensate Drain Pan Design

Details the one-piece drain pan design and condensate removal.

4.5 Electric Heater Integration

Explains the electric heater type, capacity, and safety features.

4.6 Fan Motor Assembly Details

Covers fan motor codification, speeds, and maintenance access.

5 - Atmosphera Configurations

6 - Control Systems

Control System Overview

Overview of control options including thermostats, numeric controllers, and switches.

Room Thermostat Control Configurations

Details standard and alternative configurations for thermostat-only control.

7 - Technical Specifications

7.1 Valve Specifications

Describes electrothermal actuators and two/three-way valve bodies.

7.2 Flexible Water Pipe Details

Details the materials, characteristics, and specifications of flexible water pipes.

7.3 Heating/Cooling Changeover Switch

Technical specifications for the heating/cooling changeover switch.

8 - Accessories

8.1 Carrier Electronic Thermostat

Features of an elegant room thermostat for optimized comfort.

8.2 Maestro Zone User Interface

Details the Zone User Interface functions and connectivity.

8.3 Wall-mount Base for Zone UI

Describes the mounting base for the Zone User Interface.

8.4 Maestro Wall-mounted Sensor

Features of a wall-mounted room sensor.

8.5 Three-speed Wall Thermostat

Details functions of a wall thermostat for Maestro controllers.

8.6 Condensate Drain Pump

Explains the operation, features, and introduction of condensate drain pumps.

9 - Performance Data

9.1 Cooling Capacity - Water Coil

Presents cooling capacity data for water coils across various sizes and conditions.

9.2 Heating Capacity - Water Coil

Provides heating capacity data for water coils across various sizes and conditions.

9.3 Water Coil Pressure Drops

Graphs showing pressure drops for water coils based on water flow.

9.4 Water Valve Pressure Drops

Graphs illustrating pressure drops for 2-way and 3-way water valves.

9.5 Sound Power Levels

Provides sound power level data for different unit sizes and configurations.

9.5.3 Return Air Plenum Attenuation

Correction factors for sound power levels when a return air plenum is used.

9.5.4 Sound Damper Attenuation

Attenuation values for an optional sound damper in the return air.

9.6 Electrical Data

Detailed electrical data including fan motor speed, power, and air flow.

9.7 Air Flow Data

Static pressure curves and plenum box pressure drops for various air flows.

9.7.2.1 Plenum Box Pressure Drops

Pressure drops for octopus plenum boxes based on spigot count.

9.7.3 Sound Damper Pressure Drops

Pressure drops associated with return air sound dampers.

10 - Codification

Unit Type, Size, and Chassis

Defines unit types, sizes, air flow ranges, and chassis/insulation types.

Control Configuration Codification

Detailed codification for various control configurations and features.

Coil Type and Water Connections

Specifies coil types and water connection configurations.

Fresh Air Supply Options

Details fresh air supply options and controller types.

Return Air Spigot Configurations

Defines the number and types of return air spigots.

Supply Air Spigot Configurations

Defines the number and types of supply air spigots.

Fan Motor Speed Wiring

Explains fan motor speed wiring configurations and terminal connections.

Modification Index and Specials

Covers modification indices and special product designations.

11 - Specification Guide

Numerical Control Features

Details the functions and capabilities of numerical control systems.

Related product manuals