Service Settings – Wireless Remote RG66
Service Settings are only accessible through the wireless remote 
control.
Caution: Read and understand the function changes you wish to make 
in advance. The remote will not read the parameters in the unit.
While many settings can be accessed, we find only the ones listed below may need 
adjustment from default.
F1 Auto-Start – Turn OFF or turn back ON
F2 Heating Temperature Compensation – Adjust an offset based on thermal stratification 
within the space.
F4 Indoor Fan Motor Speed Control after Set Point is Reached – Changes Heat fan speed 
after set point is reached.
F7 Cooling Temperature Compensation – Adjust an offset based on thermal stratification 
within the space.
1. Before using the service functions of the remote, turn 
OFF the indoor unit with the remote.
2. Remove batteries from Wireless Controller, recycle power 
to system and reinstall batteries.
3. Pointing the Wireless Controller at the Indoor unit’s 
receiver, simultaneously press MODE and             
TIMER ON for 5 seconds. When the display reads “F1” 
you are in SERVICE FUNCTION mode.
4. Use TEMP + or − to find and display the parameter you 
want to change.
5. When the parameter you want to change appears, press 
MODE (parameters displayed after pressing MODE are 
default values only, NOT the values stored in the unit. The 
values are stored in the unit, not the controller. Pressing 
MODE only displays the default value for that setting.).
6. To change the parameter use the TEMP + or − until the 
value you want appears.
7. Press FAN to confirm the new setting value and transmit 
it to the Indoor Unit.
8. Repeat steps 3 thru 6 for any other parameter you are 
changing.
9. When finished, remove batteries from the remote and 
press any button to clear the screen and then replace the 
batteries and operate the system normally. 
Continued on next page