SPECIFICATIONS
Heating Capacity and Efficiency 040-10 040-12 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20
Input
High
Heat
(BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000
Output
High
Heat
(BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000
Efficiency AFUE % (ICS) 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5 95.5
Certified Temperature
Rise Range ºF (ºC)
High Heat
40 - 70
(22 - 39)
35 - 65
(19 - 36)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
Airflow Capacity and Blower Data 040-10 040-12 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20
Rated External Static
Pressure (in. WC.)
Heating 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Airflow Delivery
@ Rated ESP (CFM)
High Heat 820 1000 840 980 1040 1695 1510 1680 2245 2175
Cooling 905 1050 1130 1420 1600 1970 1545 2065 2105 2035
Cooling Capacity (tons)
400 CFM/ton 2 2.5 2.5 3.5 4 5 4 5 5 5
350 CFM/ton 2.5 3 3 4 4.5 5.5 4.5 6 6 6
Direct-Drive Motor Type Permanent Split Capacitor (PSC)
Direct-Drive Motor HP 0.5 0.5 0.5 0.5 0.75 1 0.5 1 1 1
Motor Full Load Amps 6.2 6.8 6.2 6.8 7.9 13.8 6.5 13.8 14.1 14.1
RPM Range 500 -1150
Speed Selections 4 5 4 5 5 5 4 5 5 5
Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 10 11 x 11 11 x 11
Air Filtration System Field Supplied
Filter Used for Certified Watt Data* KGAWF**06UFR
Electrical Data 040-10 040-12 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20
Input Voltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 6.8 8.3 7.0 8.4 9.6 14.5 7.6 14.6 14.9 14.9
Unit Ampacity Amps 9.5 11.4 9.7 11.5 13.0 19.1 10.4 19.2 19.6 19.6
Minimum Wire Size AWG 14 14 14 14 14 12 14 12 12 12
Maximum Wire Length
@ Minimum Wire Size
Feet 39 32 38 32 28 30 35 29 29 29
(M) (11.9) (9.8) (11.6) (9.8) (8.5) (9.1) (10.7) (8.8) (8.8) (8.8)
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recom-
mended)
Amps 15 15 15 15 15 20 15 20 20 20
Transformer Capacity (24vac output) 40 VA
External Control Power
Available
Heating 27.9 VA
Cooling 34.6 VA
Controls 040-10 040-12 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20
Gas Connection Size 1/2" - NPT
Burners (Monoport) 2 2 3 3 4 4 5 5 6 7
Gas Valve (Redundant) Manufacturer White Rogers
Minimum Inlet Gas pressure (in. wc) 4.5
Maximum Inlet Gas pressure (in. wc) 13.6
Gas Conversion Kit - Natural to Propane KGANP50011SP
Gas Conversion Kit - Propane to Natural KGAPN42011SP
Manufactured (Mobile) Home Kit KGAMH0601KIT N/A
Ignition Device Silicon Nitride
Limit Control 165 180 165 180 170 200 180 180 160 155
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay) 90 seconds
Communication System none
Thermostat Connections Com24V,R,W,G,Y
Accessory Connections EAC (115vac); HUM (24vac)