7. Temperature and probe reading adjustments.
Press the On/Off button for 7 seconds and 50 will appear on
screen.
Press the (+) button until 55 appears.
55
On / Off Mode F an
7.1 Temperature limit for cold operations.
Press the On/Off button again and Cool and Set will appear.
Press (+) or (-) to adjust the set limit required. The
temperature range is from 10 ºC to 30 ºC
Recommended 19 ºC. (By default 10 ºC).
7.2 Temperature limit for heat operations.
Press the On/Off button again and Heat and Set will appear.
Press (+) or (-) to adjust the set limit required. The
temperature range is from 10 ºC to 30 ºC
Recommended 26 ºC. (By default 30 ºC).
IIMPORTANT
Users can change the settings on the thermostat screen without
taking the temperature limits into account, although the thermostat
will work according to the settings established (Sections 7.1 and 7.2)
19
Cool
S ET
ºC
On / Off Mode F an
26
Heat
S ET
ºC
On / Off
Mode Fan