EasyManua.ls Logo

Carrier F80CTL - Above Sea Level)

Carrier F80CTL
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F80CTL and G80CTL: Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
36
* Orifice numbers 43 are factory installed
USA
7001 to
8000 (2134
to 2438)
650 44 3.6/1.6 43 3.2/1.4 43 3.4/1.5 43 3.5/1.5
675 44 3.3/1.5 44 3.5/1.5 44 3.6/1.6 43 3.2/1.4
700 45 3.8/1.6 44 3.2/1.4 44 3.3/1.4 44 3.4/1.5
725 46 3.7/1.6 46 3.8/1.7 45 3.7/1.6 44 3.2/1.4
750 46 3.4/1.5 46 3.6/1.5 46 3.7/1.6 46 3.8/1.6
775 47 3.6/1.6 47 3.8/1.6 46 3.4/1.5 46 3.6/1.5
800 47 3.4/1.5 47 3.5/1.5 47 3.7/1.6 47 3.8/1.6
825 48 3.7/1.6 48 3.8/1.6 47 3.4/1.5 47 3.6/1.5
USA
8001 to
9000
(2438 to
2743)
625 44 3.3/1.5 44 3.5/1.5 44 3.6/1.6 43 3.2/1.4
650 45 3.7/1.6 44 3.2/1.4 44 3.3/1.4 44 3.4/1.5
675 46 3.6/1.6 46 3.8/1.6 45 3.7/1.6 45 3.8/1.7
700 47 3.8/1.7 46 3.5/1.5 46 3.6/1.6 46 3.7/1.6
725 47 3.6/1.6 47 3.7/1.6 47 3.8/1.7 46 3.5/1.5
750 48 3.8/1.7 47 3.5/1.5 47 3.6/1.6 47 3.7/1.6
775 48 3.6/1.5 48 3.7/1.6 48 3.8/1.7 47 3.5/1.5
USA
9001 to
10,000
2743 to
3048)
600 45 3.7/1.6 45 3.8/1.7 44 3.3/1.4 44 3.4/1.5
625 46 3.6/1.6 46 3.7/1.6 46 3.8/1.7 45 3.8/1.6
650 47 3.8/1.6 46 3.4/1.5 46 3.6/1.5 46 3.7/1.6
675 47 3.5/1.5 47 3.6/1.6 47 3.7/1.6 46 3.4/1.5
700 48 3.7/1.6 48 3.8/1.7 47 3.5/1.5 47 3.6/1.6
725 48 3.5/1.5 48 3.6/1.6 48 3.7/1.6 48 3.8/1.7
Table 15 – Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Tabulated Data Based on 22,000 Btuh High-Heat/14,500 Btuh for
Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft. (305 M) Above Sea Level) (Continued)
ALTITUDE RANGE
FT. (M)
AVG. GAS HEAT
VALUE (BTUH/CU
FT.)
SPECIFIC GRAVITY OF NATURAL GAS
0.58 0.60 0.62 0.64
Orifice No.
Manifold
Pressure
High/Low
Manifold
Pressure
High/Low
Orifice No.
Orifice No.
Manifold
Pressure
High/Low
Orifice No.
Manifold
Pressure
High/Low
Table 16 – Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Tabulated Data Based on 21,000 Btuh High-Heat/14,500 Btuh
for Low-Heat Per Burner, Derated 4 Percent for Each 1000 Ft. (305 M) Above Sea level)
ALTITUDE RANGE
FT. (M)
AVG. GAS HEAT
VALUE
(BTUH/CU FT.)
SPECIFIC GRAVITY OF NATURAL GAS
0.58 0.60 0.62 0.64
Orifice No.
Manifold
Pressure
High/Low
Manifold
Pressure
High/Low
Orifice No.
Orifice No.
Manifold
Pressure
High/Low
Orifice No.
Manifold
Pressure
High/Low
USA
0 to
2000
(0 to 610)
900 42 3.2/1.5 42 3.3/1.6 42 3.4/1.6 42 3.5/1.7
925 43 3.7/1.8 43 3.8/1.8 42 3.2/1.5 42 3.3/1.6
950 43 3.5/1.7 43 3.6/1.7 43 3.7/1.8 43 3.8/1.8
975 43 3.3/1.6 43 3.4/1.6 43 3.5/1.7 43 3.7/1.7
1000 44 3.6/1.7 43 3.3/1.6 43 3.4/1.6 43 3.5/1.7
1025 44 3.4/1.6 44 3.6/1.7 43 3.2/1.5 43 3.3/1.6
1050 44 3.3/1.6 44 3.4/1.6 44 3.5/1.7 43 3.2/1.5
1075 45 3.8/1.8 44 3.2/1.5 44 3.3/1.6 44 3.4/1.6
1100 46 3.8/1.8 45 3.7/1.8 44 3.2/1.5 44 3.3/1.6
USA
2001 to
3000 (610
to 914)
800 43 3.8/1.8 42 3.2/1.5 42 3.3/1.6 42 3.4/1.6
825 43 3.5/1.7 43 3.7/1.7 43 3.8/1.8 42 3.2/1.5
850 43 3.3/1.6 43 3.5/1.6 43 3.6/1.7 43 3.7/1.8
875 43 3.2/1.5 43 3.3/1.6 43 3.4/1.6 43 3.5/1.7
900 44 3.4/1.6 44 3.5/1.7 43 3.2/1.5 43 3.3/1.6
925 44 3.2/1.5 44 3.3/1.6 44 3.5/1.6 44 3.6/1.7
950 45 3.7/1.8 45 3.8/1.8 44 3.3/1.6 44 3.4/1.6
975 46 3.7/1.8 46 3.8/1.8 45 3.8/1.8 44 3.2/1.5
1000 46 3.5/1.7 46 3.6/1.7 46 3.8/1.8 45 3.7/1.8