24VNA6 / 25VNA4: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
11
VFD LEDs
The VFD is equipped with several LEDs that indicate different statuses.
Fig. 10 – VFD LED Location for Each Tonnage
WARNI N G
!
ELECTRICAL HAZARD - HIGH VOLTAGE!
Failure to follow this warning could result in personal injury or death.
Electrical components may hold charge. DO NOT remove control box
cover for 2 minutes after power has been removed from unit.
PRIOR TO TOUCHING ELECTRICAL COMPONENTS:
Verify less than zero (0) vdc voltage at VFD connections shown on
cover.
Table 2 – VFD LED Indicator Functions
LED Identification Color Function
R1 Red
Used to indicate that high voltage is present in the DC capacitors. If this LED is lit then a DC voltage greater than 40V
is present.
G1 Green Blinks when the VFD receives a message from PCM.
G2 Green On when VFD is in normal status. It is off when VFD is fault status.
G3 Green On when the VFD microcontroller relay is closed. The signal of relay is controlled by PCM.
A1 Amber On when 12V source is normal.
A2 Amber On when the main relay is closed.
HR46VP002
(2/3 Ton VFD)
HR46VQ002
(4 Ton VFD)
HR46VQ002
(4 Ton VFD)
HR46VR002
(5 Ton VFD)