Table 1—Required Charge Adjustment for Indoor Coil Model -- HP
Furnace or Fan Coil Model Number
Outdoor Model Size
13 24B 25 36 37 48 60
CNPV*18** --- / / / / / /
CAP**18** --- / / / / / /
CNP**24 --- / / / / / /
CNPV*19** --- / / / / / /
CAP**24 --- / / / / / /
CSPH*24 --- / / / / / /
CSPH*30** / / / / / / /
F(E,V)4(A,B,C)NF002 +0.19 --- --- --- --- / /
CAP**30 / --- / / / / /
CNP**30 / --- / / / / /
CNP**36 / --- --- --- --- / /
F(E,V)4(A,B,C)N(B,F)003 / --- --- --- --- / /
CAP**36 / --- --- --- --- / /
CNP**42 / +.50 --- --- +.7 5 / /
CAP**42 / +.50 --- --- +.75 / /
CSPH*36 / / --- --- +.75 / /
CSPH*42** / / +.75 +.75 +.75 / /
CNP**31** / / +.75 +.75 +.75 / /
CNP**48 / / +.75 +.75 +.75 --- /
CSPH*48** / / +.75 +.75 +1.00 --- /
CNP**37 / / / / / / /
CNP**43 / / / / / / /
CAP**48 / / / +.75 +1.00 --- /
CNP**60 / / / / +1.00 --- ---
CSPH*60 / / / / +1.00 --- ---
F(E,V)4(A,B,C)N(B,F)005 / / +.75 +.75 +1.00 --- /
F(E,V)4(A,B,C)NB006 / / / / +1.00 +2.2 +1.00
CAP**60 / / / / / +2.2 +1.00
CNP**61 / / / / / / /
/ = Comb. not allowed
--- = No charge adjust for ID
Table 2—Required Charge Adjustment for Indoor Coil Model -- AC
Furnace or Fan Coil Model Number
Outdoor Model Size
13 24B 25 36 37 48 49 60
CNPV*18** ---
/ / / / / / /
CAP**18** ---
/ / / / / / /
CNP**24 --- --- ---
/ / / / /
CNPV*19** ---
/ / / / / / /
CAP**24 --- --- ---
/ / / / /
CSPH*24 --- --- ---
/ / / / /
CSPH*30**
/
--- ---
/ / / / /
F(E,V)4(A,B,C)NF002 +0.19 --- --- ---
/ / / /
CAP**30
/
--- ---
/ / / / /
CNP**30
/
--- ---
/ / / / /
CNP**36
/
--- --- --- ---
/ / /
F(E,V)4(A,B,C)N(B,F)003
/
--- --- --- ---
/ / /
CAP**36
/
--- +.50 --- ---
/ / /
CNP**42
/
+.50 +.50 --- +.75
/ / /
CAP**42
/
+.50 +.50 --- +.75
/ / /
CSPH*36
/
+.50 +.50 --- +.75
/ / /
CSPH*42**
/
+.50 +.50 +.75 +.75
/ / /
CNP**31**
/
+.50 +1.25 +.75 +.75
/ / /
CNP**48
/
+.50 +1.25 +.75 +.75 --- ---
/
CSPH*48**
/
+.625 +1.25 +.75 +1.00 --- ---
/
CNP**37
/
+.625 +1.25 +.75 +1.00 --- ---
/
CNP**43
/
+.625 +1.25 +.75 +1.00 --- ---
/
CAP**48
/ / /
+.75 +1.00 --- ---
/
CNP**60
/ / / /
+1.00 --- +0.125 ---
CSPH*60
/ / / /
+1.00 --- +0.125 ---
F(E,V)4(A,B,C)N(B,F)005
/
+.625 +1.25 +.75 +1.00 --- +0.125
/
F(E,V)4(A,B,C)NB006
/ / /
+.75 +1.00 +1.5 +.625 +1.00
CAP**60
/ / / / /
+1.5 +.625 +1.00
CNP**61
/ / / / /
+1.5 +.625 +1.00
/ = Comb. n ot allowed
--- = No charge adjust for ID

Other manuals for Carrier Infinity 25VNA8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier Infinity 25VNA8 and is the answer not in the manual?

Carrier Infinity 25VNA8 Specifications

General IconGeneral
BrandCarrier
ModelInfinity 25VNA8
CategoryHeat Pump
LanguageEnglish

Related product manuals