Loading...
®®© !
@
%
Fig. 3--Recessed Mount Backplate
Fig. 4_urface Mount Backplate
A03186
A03187
@@@
Recessed terminal
btock in wal_ 1//2"
,_ wide by 2 I/8" high
@.-.R......oMooo,
%
-- Interlocking Tabs (4)
Fig. 6--Recessed Mount Assembly
Zza:s:zzz_
Fig. 7--Surface Mount Assembly
A03190
A03191
A04017
Fig. 5--Thin Decorative Backplate
c. Discard or recycle old thermostat.
NOTE: Mercury is a hazardous waste and MUST be disposed of
properly.
3. Select Infinity Control TM mounting plastic (recess mount or
surface mount and decorative backplate if desired).
4. Route wires through large hole in mounting plastic. Level rear
plastic against wall (for aesthetic value only - Infinity Con-
trol TM need not be level to operate properly) and mark wall
through two mounting holes.
5. Drill two 3/16 inch mounting holes in wall where marked.
6. Secure mounting plastic to wall using two screws and anchors
provided.
7. Adjust length and routing of each wire to reach each wire
entry on the connector baekplate. Strip V4 inch of insulation
fi'om each wire.
A03188
Fig. 8--Large Decorative Backplate
8. Match and connect thermostat wires to proper terminals on
User Inter_ace backplate. See wiring diagram figures 12, 13
and 14.
A Green Data A
B Yellow Data B
C White 24VAC (Corn)
D Red 24VAC (Hot)
NOTE: It is not mandatory that the above color code be used, but
each ABCD connection in the system MUST be wired consis-
tently. A separate ABCD Connector comes inside packaging and
should be used when connecting to the furnace (or fan coil). (See
Fig. 10)
NOTE: Insert connector properly into circuit board.