19
S To set the desired humidity level during cooling, touch COOLING
HUMIDITY.
d Use the Up (Y) and Down (B) buttons to set the maximum dehu-
midification level at NONE or between 55--65%.
d Touch YES or NO for the system to over--cool the conditioned
space by up to 3_ F to remove as much humidity out of the air as
possible.
d Press SAVE when finished, or CANCEL to discard any changes.
Vacation Comfort Profile Fresh Air Control
S If a ventilator is installed in your home, select the amount of fresh air to
circulate during heating mode by touching HEATING FRESH AIR.
S You will have the option of choosing between AUTO, MANUAL,or
OFF.
NOTE: This option may not be available with the ERVXXNVA ventilator due to
its simplified control design.
d The AUTO setting will allow the user to choose the maximum fresh
air that the ventilator will provide. Selections are Low, Medium or
High.
d The MANUAL setting allows you to select the percentage of fresh
air to supply to your home.
d Use the Up (Y) and Down (B) buttons to set the desired ventilator
speed level.
d Press SAVE when finished, or CANCEL to discard any changes.
S If applicable, select the amount of fresh air to circulate during cooling
mode by touching COOLING FRESH AIR. Again, you will have the
option of choosing among AUTO, MANUAL and OFF.