SYSTXCCUID01-- V
Infinityt Control
Installation Instructions
HOLD
COOL
HEAT
OFF
ZONE
I
NFINITY
â„¢
S
YSTEM
A04031
Fig. 1 -- Infinityt Control
NOTE: Read the entire instruction manual before starting the
installation.
US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1.........................
INTRODUCTION 1...................................
INSTALLATION AND START--UP OVERVIEW 2..........
INSTALLATION 2....................................
INSTALLING INFINITY CONTROL 3....................
INITIAL POWER--UP 5................................
QUICK START 7.....................................
INSTALL / SERVICE MENUS 8.........................
EQUIPMENT SUMMARY MENU 8......................
INSTALL MENU 8....................................
SETUP MENU 8......................................
CHECKOUT MENUS 13...............................
SERVICE MENUS 14..................................
OPERATIONAL INFORMATION 15.....................
TROUBLESHOOTING 17..............................
SYSTEM MALFUNCTION SCREEN 18..................
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions
included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical
Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. When you see this symbol
on
the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING,andCAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious hazards,
which will result in severe personal injury or death. WARNING
signifies hazards, which could result in personal injury or death.
CAUTION is used to identify unsafe practices, which may result
in minor personal injury or product and property damage. NOTE
is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
INTRODUCTION
The Infinity System consists of several intelligent communicating
components which includes the Infinity Control (or User
Interface), variable speed furnace or FE fan coil, 2--stage AC or HP
and Infinity Packaged Products, which continually communicate
with each other via a four--wire connection called the ABCD bus.
Commands, operating conditions, and other data are passed
continually between components over the ABCD bus. The result is
a new level of comfort, versatility, and simplicity.
All Infinity furnaces or fan coils are variable--speed and multi stage
for maximum flexibility, efficiency, and comfort. They support
controlled ventilation, humidification, dehumidification, and air
quality control. Either an Infinity (communicating), or a standard
24VAC controlled outdoor unit may be used.
When using conventional outdoor units, the Infinity furnace or fan
coil provides the 24 volt signals needed to control them. Also, the
Infinity Network Interface Module (P/N SYSTXCCNIM01) allows
connection of a Carrier HRV or ERV without the need for a
separate wall control.
All system components are controlled through the wall mounted
Infinity Control, which replaces the conventional thermostat and
provides the homeowner with a single wall control for all features
of the system.
Question and Answer IconNeed help?

Do you have a question about the Carrier Infinity SYSTXCCUID01-V and is the answer not in the manual?

Carrier Infinity SYSTXCCUID01-V Specifications

General IconGeneral
BrandCarrier
ModelSYSTXCCUID01-V
SeriesInfinity
DisplayColor touchscreen
ZoningYes
Energy ManagementYes
Power Source24V AC
ColorWhite
CompatibilityInfinity System
ConnectivityWi-Fi
Control FeaturesRemote access, scheduling

Summary

Installation Instructions

Safety Considerations

Critical safety warnings and precautions for installation and operation.

Introduction to Infinity System

Overview of the intelligent communicating components and system benefits.

Installation and Setup Overview

Electrical Safety Precautions

Electrical Operation Hazard Warning

Warning regarding potential injury or death from improper electrical handling.

Initial Power-Up and System Configuration

Power Up Sequence

Steps for initial system power-up and equipment communication.

Selecting System Components

Selecting Outdoor Unit

Identifying and configuring the outdoor unit type and size.

Quick Start Guide

Install / Service Menus

Setup Menu Overview

Accessing and navigating the system setup options.

Thermostat Configuration

Configuring thermostat settings like auto mode, deadband, and offsets.

Checkout Menus

Service Menus

Service - Last 10 System Events

Reviewing the last 10 recorded system events and faults.

Troubleshooting

Infinity Control Power Issues

Diagnosing and resolving issues with the Infinity Control not powering up.

Indoor Unit Not Found Error

Troubleshooting communication errors for the indoor unit.

Outdoor Unit Not Found Error

Troubleshooting communication errors for the outdoor unit.

System Malfunction Screens

Fan Coil Malfunction Codes

Understanding flash codes for fan coil system malfunctions.

Furnace Malfunction Codes

Understanding flash codes for furnace system malfunctions.

Outdoor Unit Malfunction Codes

Understanding flash codes for outdoor unit system malfunctions.