6
Conguration options enable the installer to congure the
User interface for a particular installation. These settings
are not presented to the homeowner and therefore must
be properly set by the installer.  
Following is a list of parameters available, a description of 
their range, and their factory default settings.
Step 3 — Set NUI Installer Conguration
Installation (Table 1)
SYSTEM TYPE 100
This parameter is used by the Installer in order to 
determine the System type:
17 1
1.  A2W Monobloc xed Water Temperature 
Value (dry contacts)
2.  A2W Monobloc  Climatic Curve setup (dry 
contacts)
3.  A2W Monobloc  Comfort with NUI
4.  Blank
5.  Blank
6.  A2W Monobloc RS485
7.  EOL Test Application
USER INTERFACE 
TYPE 
101
This parameter is dening if Comfort User 
Interface (NUI) is used and if it's used like a 
thermostat or a programmer
02 0
0.  Not Used (Input Relay active/SUI)
1.  NUI Installed
2.  NUI used as programmer
NUI SW VERSION 102 NUI Software Version - -
Read
value
NUI SW RELEASE 103 NUI Software Release - -
Read
value
OUTPUT TEST 104
This feature will permit to force Output ON up to 
when No Test code is selected again:
09 0
0.  No test
1.  Water Pump
2.  Defrost / Terminal fan coil
3.  External heat source / Humidier or 
dehumidier
4.  Alarm & Defrost / Alarm
5.  Heater Exchanger EH
6.  3 Way valve for sanitary hot water
7.  SUI Alarm (Code 16) low voltage ( 12v open 
collector)
8.  Defrost Alarm Output low voltage ( 12v open 
collector)
RESET PUMP TIME 105
This parameter resets the water pump time to 
zero.
000 165 000
HUMIDITY/ EXT HEAT 
SOURCE CONTROL
106
This parameter will select Humidity Control 
Output or Heat Source Output on J7 Pin3. 
12 2
1. External Heat Source 
2. Humidity Output
HUMIDITY LIMIT 107
This parameter denes the Humidity threshold 
limit to enable the output for the external de-
humidier system.
20 100 100
FEATURE
PARAMETER 
NUMBER
DESCRIPTION
VALUE 
RANGE
DEFAULT 
VALUE
INSTALLER 
VALUE
Min Max