LADDER WIRING DIAGRAM
C;11
C;11
C;21
C
C;11
L1
L2
USE COPPER CONDUCTORS ONLY
FIELD SUPPLY
208/230 VAC. 60 HZ. 1PH
C;21
EQUIP GND
DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING
BLK
BLK
BLK
BLK
YEL
YEL
YEL
YEL
YEL
CCH
WHEN USED
CHS
BLK
BLK
BRN
BLU
H
C
F
CAP
OFM
COMP
S
C
R
C;13
IFB
24VAC/R
SEE NOTE 7
FUSE
BLK
YEL
GRN/YEL
3 AMP
C;11
IFB;COM/C
IFB;COM
BRN
RED
TO ACCESSORY
ELECTRIC HEAT
BRN
WHT
VIO
PNK
GRY
1
5
4
3
2
PLUG
COM
208
230
C
24V
TRAN
SEE NOTE 6
SEE NOTE 6
OF2OF1
BLK BLK
TO CONTACTOR
TO CONTACTOR
WITHOUT FUSES
WITH FUSES
BLK
BLK
L1
L2
FOR WIRING WITH ELECTRIC HEATERS SEE SCHEMATIC ON
HEATER ACCESSORY
SINGLE POINT CONNECTION SHOWN
L1
BLK
L2
YEL
YEL
TO
ELECTRIC
HEATER
TO
ELECTRIC
HEATER
YEL
DR ON DB
DIP SWITCH SETTINGS
30 MINUTES
DEFAULT
60 MINUTES
90 MINUTES
120 MINUTES
30 60
ON
QUIET
SHIFT
OR
OR
OR
OFF
(DEFAULT)
12
3
1
2
312
3
1
2
3
12
3
FIELD SELECTABLE OPTIONS FOR TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)
90
SPEED
UP
JUMPERED TEST PINS (USE METAL OBJECT)
FIELD SPEED-UP CYCLE
1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS
COMPRESSOR OFF DELAY.
2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.
3) PERMANENT SHORT WILL BE IGNORED.
DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.
THE COMPRESSOR WILL SHUT OFF FOR 30 SEC. ON DEFROST
INITIATION AND TERMINATION IN THE “QUIET SHIFT” ON
POSITION.
T + 60
G
G
O
COOLING FAN LOGIC
ENERGIZED DE-ENERGIZED
T
RED
BLK
PNK
BLK
SOL
PLUG
G
GRN
T-STAT
W3
DH
W2
Y2
Y1
O
R
BLU
VIO
WHT
YEL
RED
ORN
PNK
C
BRN
DH
R
W2
W3
Y1
Y2
G
O
C
P1-3
P2-3
P2 -2
P2-1
BRN
DB
YEL
LPS
DFT
YEL
WHT
RED
ORN
P1 -8(O)
P1 -7(R)
P1 -6(W2)
P1 -5(Y)
P2 -1(O)
T1
RVS
P2 -4(T2)
BLK
BRN
C1
C2
BRN
C
BLU
BLK
HPS
BLK
BLU
Y
P3 -1
P3 -2
BLU
BLU
BLU
PNK
PNK
DB
24V Screw
Terminals
Control Board
Connector
1
2
3
4
5
6
7
8
9
10
11
12
IFM
BRN
15
14
6
13
2
12
1
3
10
9
5
11
7
4
GRN
YEL
BLK
WHT
PNK
RED
BRN
ORN
GRA
ORN
BLU
VIO
BLK
WHT
345420-101 REV.-
GRN
YEL
BLK
WHT
PNK
VIO
VIO
RED
BRN
ORN
BRN
GRY
CFM ADJUST (BLK)
ON/OFF DELAY (WHT)
AUX HEAT (VIO)
AC/HP SIZE (BLU)
SYSTEM TYPE (ORN)
J1
SEE NOTE 9
A190330
Fig. 16 Cont. -- Ladder Wiring Diagram with Advanced Dehumidification (AD) FIOP 208/230--1 --60
50VR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier Performance 50VR-A and is the answer not in the manual?

Carrier Performance 50VR-A Specifications

General IconGeneral
BrandCarrier
ModelPerformance 50VR-A
CategoryHeat Pump
LanguageEnglish

Related product manuals