111
T-343
Table 1-3 Auto Restart Sequencing (Continued)
Series
Attempt
Number
Intake
Heater
Energized
in
Seconds
Fuel
Solenoid
Engaged
Engine
Crank
Duration
(Seconds)
Engine
Rest
Duration
(Seconds)
Engine Status
4 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will deenergize.
b. Fuel solenoid will deenergize.
c. Crank output will deenergize.
d. Overcrank LED will flash four times. Wait
two seconds and repeat.
e. Unit will rest five hours and proceed to the
next series.
5 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will deenergize.
b. Fuel solenoid will deenergize.
c. Crank output will deenergize.
d. Overcrank LED will flash five times. Wait
two seconds and repeat.
e. Unit will rest five hours and proceed to the
next series.
6 30 X Up To 15 25
If the engine starts:
a. Run sequence begins.
If the engine fails to start:
a. Intake heater will deenergize.
b. Fuel solenoid will deenergize.
c. Crank output will deenergize.
d. Overcrank LED will illuminate solid and
lock out future crank attempts.
e. To reset, turn unit power switch OFF and
back ON.