Diesel Generator Set
OPERATIONS AND SERVICE
For
69RG15
Generator Set Units
RG2059 to RG2100 Series
T-361 Rev F 09/19

Table of Contents

Questions and Answers

  • K
    kbyrdAug 14, 2025
    Why Carrier RG2059 engine will not start?
    • J
      John MonroeAug 14, 2025
      If your Carrier Inverter engine won't start, it could be due to several reasons: a battery that is insufficiently charged (charge it), a defective battery terminal post or battery (check it), bad electrical connections at the starter (correct them), or a bad fuse F5 (replace it).
  • J
    Jessica MuellerAug 17, 2025
    What to do if Carrier Inverter engine starts then stops?
    • J
      Jeffrey BennettAug 17, 2025
      If your Carrier Inverter engine starts and then stops, consider these potential causes: not enough fuel in the tank (refer to Section 2.10/Section 2.11), a restricted fuel filter (replace it), an open wiring circuit to the fuel solenoid (check it), or a defective fuel solenoid (replace it). Also, check for leaks in the fuel system.
  • S
    Shawn PowellAug 21, 2025
    What to do if Carrier RG2059 starter motor malfunctions?
    • H
      hollandmakaylaAug 21, 2025
      If the starter motor on your Carrier Inverter is malfunctioning, the following could be the cause: the battery is insufficiently charged (charge it), battery cable connections are loose or oxidized (check/replace them), battery cables are defective (check/replace them), or the ignition switch is defective (replace it).
  • C
    Chris BrownAug 25, 2025
    What to do if Carrier RG2059 starter motor cranks but fails to start?
    • V
      Virginia SpencerAug 25, 2025
      If the starter motor cranks but the Carrier Inverter fails to start, possible causes include water inside the fuel system (drain sump), plugged fuel filters (replace them), or fuses F1, F2, F3, and F4 are bad (check/replace). Also check/correct loose or no connection between wire harness and Electronic Governor Module (EG).
  • J
    jacksonbarryAug 27, 2025
    Why Carrier Inverter engine will not shut off?
    • Y
      yperryAug 27, 2025
      If your Carrier Inverter engine won't shut off, it could be due to a loose ground connection (clean/tighten it) or an improperly seated fuel solenoid (correct it).
  • N
    Nicholas RyanAug 30, 2025
    What causes Carrier Inverter alternating current generator no voltage?
    • A
      Andre LawsonAug 30, 2025
      If your Carrier Inverter's alternating current generator has no voltage, the causes could be loss of rotor magnetism (replace it), a tripped circuit breaker (check CB1), an open in stator windings (replace), or it is short circuited (replace). Also, check/replace worn drive gear stripped and replace contactor not engaged.
  • M
    Melanie CarrollSep 3, 2025
    What causes Carrier Inverter malfunction in the engine starting circuit?
    • B
      Brian TranSep 3, 2025
      A malfunction in the engine starting circuit of your Carrier Inverter could stem from a defective battery (correct it) or loose electrical connections (tighten them).
  • K
    Kathleen AndersonSep 6, 2025
    Why Carrier RG2059 starter cranks and engages, but dies after a few seconds?
    • R
      Roy JohnsonSep 6, 2025
      If the Carrier Inverter starter cranks and engages, but dies after a few seconds, check the voltage drop in starter cable(s).
  • A
    alisha20Sep 10, 2025
    What causes Carrier RG2059 alternating current generator low voltage?
    • L
      Linda SawyerSep 10, 2025
      If your Carrier Inverter's alternating current generator has low voltage, the cause could be high resistance connections, where connections are warm or hot (tighten them).

Carrier RG2059 Series Specifications