Carrier RG2059 Series - General Generator Set Maintenance; Maintenance of Painted Surfaces; Checking and Replacing Shockmounts; Figure 5.12 Battery Charger (Pids Prior to RG2059)

Carrier RG2059 Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5–13 T-361
Figure 5.12 Battery Charger (PIDs Prior to RG2059)
Figure 5.13 Battery Charger (PIDs RG2059 and Up)
43. Replace the voltage controller cables and secure the voltage controller to the channel assembly using the 1/
4” bolts/washers (4). Make sure to also secure the two wire harness clamps using the left side voltage con-
troller mounting bolts.
44. Replace the intake air hose and clamp the air intake hose to the intake port.
45. Re-connect the battery.
46. Replace and secure the unit cover.
5.7 GENERAL GENERATOR SET MAINTENANCE
5.7.1 Maintenance of Painted Surfaces
The unit is protected against the corrosive atmosphere in which it normally operates by a special paint system.
However, should the paint system be damaged, the base metal can corrode. If the paint system is scratched or
damaged, do the following:
1. Clean area to bare metal using a wire brush, emery paper or equivalent cleaning method.
2. Immediately following cleaning, spray or brush on a zinc rich primer.
3. After the primer has dried, spray or brush on finish coat of paint to match original unit color.
5.7.2 Checking and Replacing Shockmounts
Replacement Criteria
CAUTION
!
Continued operation with failed shockmounts may result in engine or generator damage.
Output +
Ground
Output -
Power Cable
AC Wiring from Generator
DC Wiring to 12v Battery