4–7 T-361
4.5 ELECTRONIC GOVERNOR MODULE
4.6 VOLTAGE CONTROLLER
The voltage controller has one green indicator light and one yellow indicator light. When the green light is illumi-
nated, it means that the voltage controller is receiving power. The yellow light only illuminates (flashes) to indicate
that there is a problem.
Table 4–10 Electronic Governor Modules
Fault LED flash code Possible Cause
Engine Over Speed: more than
2,530 RPM
One Long - One Short  ESS or mechanical engine problem
Actuator Wiring Disconnection.
No  signal  from  ESS  for  2
seconds  after  RPM  is  greater
than  1,000  RPM  for  10
seconds,  OR  for  5  seconds
while  engine  cranking  (no
voltage at EG pin 18).
Two Long - One Short Short ESS or wiring problem
Speed  Sensor  Disconnection.
Fuel/speed  actuator  (FS)
wiring  disconnected  or  open
circuit.  Coil  Resistance  Spec:
2.8 ohm +
 10%.
Two Long - Three Short  FS or wiring problem
EG  supply  voltage  is  greater
than 26V.
Two Long - Seven Short  EG or alternator problem
Table 4–11 Voltage Controller
Green LED Fault Possible Cause/Remedy
LED not illuminated No power to the voltage controller Contactor failed
Check  line  side  power  on
contactors
Yellow LED flash Code Fault Possible Cause/Remedy
One Long - Three Short  Over Voltage Error  Engine speed, check
One Long - Four Short  Under Voltage Error  Engine speed, check