T-361 4–6
4.4 AUTO RE-START OPTION
Mechanical Noise Bad bearing Replace
Rotor rubbing on stator Replace
Loose laminations Replace
Loose or misaligned coupling Check drive gear
Generator frame produces
shock when touched
Static charge Check ground to frame
Table 4–9 Auto Re-Start Option
Condition Possible Cause Remedy/Reference Section
When the Ignition switch is
placed in the RUN position,
nothing happens− no lights
illuminate
Wait 30 seconds for intake heater to be
activated
Wait
Relay defective Check/Replace
Ignition switch defective Check/Replace Switch
3 amp Fuse is bad Check and Replace Fuse
Loose connector on module Tighten connector
Auto restart module is bad Check for 12 volts at Pin 4/Replace
module
Mis-wired connectors Check/Correct wiring
Alarm sounds, but engine does
not crank
No voltage at Pin 2 of the connector Trace/Correct
Check Starter Solenoid Section 4.1.1
Auto restart module is bad Replace module
Engine starts, but the starter
does not disengage
Speed Sensor wiring loose Check/Correct
Speed Sensor is bad Replace
Auto restart module is bad Replace module
Engine starts, but shuts down
from over speed
Electronic Governor Module (EG) is bad Replace
Engine cranks, but will not start Electronic Governor Module (EG) is bad Replace
Section 4.1.1 Section 4.1.1
Engine starts, but shuts down
on low oil
Section 4.1.2 Section 4.1.2
Engine starts, but shuts down
on high water temperature
Section 4.1.6 Section 4.1.6
Table 4–8 Alternating Current Generator
Condition Possible Cause Remedy/Reference Section

Table of Contents