T-361 2–8
Table 2–2 Auto Restart Preset Values
Indicator Preset Value Description
Overspeed 2100 RPM Overspeed is the point at which the unit will signal for shutdown.
Crank Disconnect 700 RPM Crank Disconnect is the point at which the Auto Restart module
senses the engine has started and will disengage the starter.
Shutdown Lockout De-
lay
15 seconds The oil pressure and water temperature inputs are ignored
during this 15 second delay (during startup).
Intake Heater Delay 30 seconds preheat
3 minutes post heat
The delay is used during start up. The intake heater delay begins
timing after the auto restart module signal is received. During the
entire delay, the intake heater circuit will be energized, an indi-
cator light will be illuminated, and an alarm will sound. When the
delay expires, the unit will crank.
Crank Attempts 18 attempts A series of six attempts with three attempts in each series for a
total of 18 attempts, refer to Table 2–3, Auto Restart Sequenc-
ing.
Table 2–3 Auto Restart Sequencing
Series Attempt Number 1 Engine Status:
If the engine starts:
1. Run sequence begins
2. Intake heater remains energized for 3 minutes
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will flash once. Wait two seconds and repeat.
5. Unit will rest 30 minutes and proceed to the next series.
Intake Heater Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine Crank Duration
(Seconds)
Up to 15
Engine Rest Duration
(Seconds)
25
Series Attempt Number 2 Engine Status:
If the engine starts:
1. Run sequence begins
2. Intake heater remains energized for 3 minutes
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will flash twice. Wait two seconds and repeat.
5. Unit will rest 30 minutes and proceed to the next series.
Intake Heater Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine Crank Duration
(Seconds)
Up to 15
Engine Rest Duration
(Seconds)
25

Table of Contents