2–9 T-361
Series Attempt Number 3 Engine Status:
If the engine starts:
1. Run sequence begins.
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will flash three times. Wait two seconds and 
repeat.
5. Unit will rest five hours and proceed to the next series.
Intake  Heater  Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine  Crank  Duration
(Seconds)
Up to 15
Engine  Rest  Duration
(Seconds)
25
Series Attempt Number 4 Engine Status:
If the engine starts:
1. Run sequence begins.
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will flash four times. Wait two seconds and repeat.
5. Unit will rest five hours and proceed to the next series.
Intake  Heater  Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine  Crank  Duration
(Seconds)
Up to 15
Engine  Rest  Duration
(Seconds)
25
Series Attempt Number 5 Engine Status:
If the engine starts:
1. Run sequence begins.
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will flash five times. Wait two seconds and repeat.
5. Unit will rest five hours and proceed to the next series.
Intake  Heater  Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine  Crank  Duration
(Seconds)
Up to 15
Engine  Rest  Duration
(Seconds)
25
Series Attempt Number 6 Engine Status:
If the engine starts:
1. Run sequence begins.
If the engine fails to start:
1. Intake heater will de-energize.
2. Fuel solenoid will de-energize.
3. Crank output will de-energize.
4. Overcrank LED will illuminate solid and lock out future crank 
attempts.
5. To reset, turn unit power switch OFF and back ON..
Intake  Heater  Energized
in Seconds
30
Fuel Solenoid Engaged X
Engine  Crank  Duration
(Seconds)
Up to 15
Engine  Rest  Duration
(Seconds)
25
Table 2–3 Auto Restart Sequencing (Continued)