THERMIDISTAT CONTROL CONFIGURATION RECORD
Date
Owner/Operator Thermidistat Model No.
A) Hardware Configuration
Switch A .... AC/HP Select. (OFF = AC)
Switch B .... 1 or 2-Speed Compressor. (OFF = 1-Speed)
Switch C .... Smart Recovery. (OFF = Enable)
Switch D .... Installer Test. (OFF = Disable)
B) Mode Settings
Hold (On or Off)
Mode (Off, Heat, Cool, Auto, Eheat)
.... Heating Set Point Value
.... Cooling Set Point Value
Fan (Auto or On)
C) Configuration Options
1 ...... Anticipator (1-9: factory default = 3)
2 ...... Clean Filter Timer (Off or 1-9: factory default = 2)
3 ...... Fahrenheit or Celsius (F or C: factory default = F)
4 ...... Fan On with W (Off or On: factory default = Off)
5 ...... Variable Speed ICM Motor (Off or On: factory default = Off)
6 ...... Cooling Lockout Below 55°F (Off or On: factory default = Off)
7 ...... Variable Speed Superdehumidify (Off or On: factory default = Off, or Not Available)
8 ...... Auxiliary Heat Lockout Setting (Off or 5-55°F: factory default = Off, or Not Available)
9 ...... Intelligent Heat Staging Selection (Off or On: factory default = Off, or Not Available)
10 ...... HybridHeat Equipment Selection (Off or O:nfactory default = Off, or Not Available)
11 ...... Balance Point Setting (Off or 5-55°F: factory default = Off, or Not Available)
12 ...... Defrost Heat Select (0, 1, 2, 3: factory default = 0, or Not Available)
13 ...... Room Temperature Offset (-5 to +5: factory default = 0)
14 ...... Heat/Cool Dead Band (0 to 6: factory default = 2)
15 ...... Enable Auto Mode (On or Off: factory default = On)
16 ...... Enable Super Comfort Heat Mode (Off or On: factory default is Off, or not Available)
17 ...... Enable Non-Programmable Operation (nP or P: factory default is P for programmable)
D) Schedule
WAKE DAY
TIME HEAT COOL TIME HEAT COOL
Mon
Tue
Wed
Thu
Fri
Sat
Sun
TIME
EVE SLEEP
HEAT COOL TIME HEAT COOL
E) Humidity Settings
Heat Mode Cool Mode
Selection
Normal Humidify
Fan Humidify
Auto Humidify
Auto and Fan Humidify
Humidify Off
Set Point% Display_
(hu)
(hu, Fan)
(hu, AUTO)
(hu, AUTO, Fan)
no set point (hu, OF)
E) Vacation Humidity Settings
Heat Mode Cool Mode
Selection Set Point% Display
Normal Humidify (hu, OUT)
Auto Humidify (hu, OUT, AUTO)
Auto and Fan Humidify (hu, OUT, AUTO, Fan)
Humidify Off no set point (hu, OUT, OF)
Selection Set Point% Display
Normal Dehumidify (d hu)
Cool to Dehumidify (d hu, COOL)
Dehumidify Off no set point (d hu, OF)
Selection Set Point% Display_
Normal Dehumidify (d hu, OUT)
Cool to Dehumidify (d hu,OUT, COOL)
Dehumidify Off no set point (d hu, OUT, OF)