About Advanced Features & Operation
Page 21
FACTORY DEFAULTS - If, for any reason it is desirable to
return all stored settings back to the factory default
settings, press the Mode button. While holding the Mode
button in, press the Down button for 5 sec. All icons will
appear. Press and hold in the Fan button until Fd
appears. This resets all factory settings. To calibrate
room temperature, press the Mode button once more.
At this point use the Up and Down buttons to calibrate
room temperature, if needed. Press the Mode button to
return to normal operation. NOTE CAUTION ON PAGE 1.
OUTSIDE SENSOR (Optional Accessory) - When connected
to terminals RS+5, RS, & GND on the back of the
thermostat, the thermostat will read the temperature from
the Outside
not control to this sensor, it is only to read outside
To read the temperature
press and hold the Mode button for 2 seconds.
The display will then only show Outside temperature.
Pressing any button will then return the display to
normal operation.
Sensor when asked to. This thermostat will
temperature.
from the Outside Sensor,
The Outside Sensor is available in a wired or wireless
version. The wired sensor can be connected to the
thermostat with
Unshielded,
See the Outside Sensor instructions for further details.
up to 500’ of 20 ga. or 300’ of 18 ga.
thermostat wire.

Other manuals for Carrier TSTATCCPF701

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TSTATCCPF701 and is the answer not in the manual?

Carrier TSTATCCPF701 Specifications

General IconGeneral
BrandCarrier
ModelTSTATCCPF701
CategoryThermostat
LanguageEnglish

Related product manuals