Page #1 background image
Its also important to regularly check vents and registers to make sure that they arent blocked, vacuum them to
clear up any potential debris.
Carrier Furnace Repair Guide
Whats Wrong With Your Furnace?
Remember to always turn your furnace completely off before opening it up to look around or attempt any x.
Get FREE Quotes from Certied Local Contractors!
Get an estimate now >>
Carrier Furnace Error Codes
Not
heating?
Circuit
Breaker/Fuse
Most likely, either the electrical system providing
your furnaces power has shorted or the power
switch has blown.
Try resetting your furnaces circuit breaker. If it has blown,
you will need to replace it.
Igniter
The furnaces igniter might either be cracked or
faulty.
Check the part for cracks, if it is then replace the igniter. If
it isnt cracked, use a multimeter to test for continuity.
Cycling
irregularly?
Thermostat
Your thermostat might be adjusting incorrectly,
causing the furnace to cycle on and off too often.
If your thermostat has an adjustable calibration scale,
adjust the heat anticipator. If this does not stabilize the
unit, you may have to replace the thermostat.
Not
blowing
hot air?
Blower
Motor
Your blower motor may have completely burnt out.
If this doesnt seem to be the case, then the
connecting belt may have simply broken.
Test to see if power is reaching the motor. If it does, but
isnt running, the motor has likely failed. If the motor runs
but air doesnt move, the connecting belt has probably
broken. Youll have to replace the belt.
Blowing
too much
air?
Control
Board
The control board regulates the amount of voltage
that reaches each functioning part. If the relay that
controls the blower motor has failed, it will
continually send voltage to the motor.
Replace the control board.
Thermostat
The contact that controls the blower motor on your
thermostat may be stuck closed, causing the
blower motor to run continuously.
Use a multimeter to check for continuity. If it appears the
thermostat is the issue, replace it.
Leaking
water?
Drain Pipe
Starting
and then
stopping
shortly
after?
Flame
Sensor
Your furnaces ame sensor monitors the burner,
detecting whether a ame is present. If it is either
defective or dirty, it will not be able to detect a
ame.
If dirty, clean the sensor using a ne abrasive pad. If faulty,
replace the ame sensor.
Is your
furnace...
The
problem
might be
your...
What's wrong? How you can x it:
Search

Other manuals for Carrier WeatherMaker 8000