(1) GAP / PEEL Sensor Test
- Click “Cal” button to check Gap Sensor and Peel Sensor values. If no issues are found,
Pass will be displayed.
(2) PEEL-OFF Test
- Click “PEEL-OFF Try” button, then check the PEEL-OFF Sensor.
- Check the PEEL-OFF Sensor as you change its value.
(Bind / unbind the sensor to change the value)
- If the value changes four times within the duration of the test, Pass will be displayed.
(3) HEAD-UP Test
- Click “Head Up Try” button to start the test.
- Move the Head Up Sensor up and down to check for any issues.
- If the values change four times within the duration of the test, Pass will be displayed.